Commission Regulation (EC) No 244/2009Show full title

Commission Regulation (EC) No 244/2009 of 18 March 2009 implementing Directive 2005/32/EC of the European Parliament and of the Council with regard to ecodesign requirements for non-directional household lamps (Text with EEA relevance)

ANNEX IIU.K.Ecodesign requirements for non-directional household lamps

1.LAMP EFFICACY REQUIREMENTSU.K.

Incandescent lamps with S14, S15 or S19 caps shall be exempted from the efficacy requirements of Stages 1 to 4 as defined in Article 3 of this Regulation, but not from Stages 5 and 6.

The maximum rated power (Pmax) for a given rated luminous flux (Φ) is provided in Table 1.

The exceptions to these requirements are listed in Table 2 and the correction factors applicable to the maximum rated power are in Table 3.

Table 1

Application dateMaximum rated power (Pmax) for a given rated luminous flux (Φ) (W)
Clear lampsNon-clear lamps
Stages 1 to 50,8 * (0,88√Ф+0,049Ф)0,24√Ф+0,0103Ф
Stage 60,6 * (0,88√Ф+0,049Ф)0,24√Ф+0,0103Ф

Table 2

Exceptions

Scope of the exceptionMaximum rated power (W)
Clear lamps 60 lm ≤ Φ ≤ 950 lm in Stage 1Pmax = 1,1 * (0,88√Ф+0,049Ф)
Clear lamps 60 lm ≤ Φ ≤ 725 lm in Stage 2Pmax = 1,1 * (0,88√Ф+0,049Ф)
Clear lamps 60 lm ≤ Φ ≤ 450 lm in Stage 3Pmax = 1,1 * (0,88√Ф+0,049Ф)
Clear lamps with G9 or R7s cap in Stage 6Pmax = 0,8 * (0,88√Ф+0,049Ф)

The correction factors in Table 3 are cumulative where appropriate and also applicable to the products covered by the exceptions of Table 2.

Table 3

Correction factors

Scope of the correctionMaximum rated power (W)
filament lamp requiring external power supplyPmax/1,06
discharge lamp with cap GX53Pmax/0,75
non-clear lamp with colour rendering index ≥ 90 and P ≤ 0,5 * (0,88√Ф+0,049Ф)Pmax/0,85
discharge lamp with colour rendering index ≥ 90 and Tc ≥ 5 000 KPmax/0,76
non-clear lamp with second envelope and P ≤ 0,5 * (0,88√Ф+0,049Ф)Pmax/0,95
LED lamp requiring external power supplyPmax/1,1

2.LAMP FUNCTIONALITY REQUIREMENTSU.K.

The lamp functionality requirements are set out in Table 4 for compact fluorescent lamps and in Table 5 for lamps excluding compact fluorescent lamps and LED lamps.

Where the rated lamp lifetime is higher than 2 000 h, the Stage 1 requirements for the parameters ‘Rated lamp lifetime’, ‘Lamp Survival Factor’ and ‘Lumen maintenance’ in Tables 4 and 5 are only applicable as from Stage 2.

For the purposes of testing the number of times the lamp can be switched on and off before failure, the switching cycle shall consist of periods comprising 1 minute on and 3 minutes off, while the other test conditions are defined according to Annex III. For the purposes of testing lamp lifetime, lamp survival factor, lumen maintenance and premature failure, the standard switching cycle according to Annex III shall be used.

Table 4

Functionality requirements for compact fluorescent lamps

Functionality parameterStage 1Stage 5
Lamp survival factor at 6 000 h≥ 0,50≥ 0,70
Lumen maintenanceAt 2 000 h: ≥ 85 % (≥ 80 % for lamps with second lamp envelope)

At 2 000 h: ≥ 88 % (≥ 83 % for lamps with second lamp envelope)

At 6 000 h: ≥ 70 %

Number of switching cycles before failure

≥ half the lamp lifetime expressed in hours

≥ 10 000 if lamp starting time > 0,3 s

≥ lamp lifetime expressed in hours

≥ 30 000 if lamp starting time > 0,3 s

Starting time< 2,0 s

< 1,5 s if P < 10 W

< 1,0 s if P ≥ 10 W

Lamp warm-up time to 60 % Φ

< 60 s

or < 120 s for lamps containing mercury in amalgam form

< 40 s

or < 100 s for lamps containing mercury in amalgam form

Premature failure rate≤ 2,0 % at 200 h≤ 2,0 % at 400 h
UVA + UVB radiation≤ 2,0 mW/klm≤ 2,0 mW/klm
UVC radiation≤ 0,01 mW/klm≤ 0,01 mW/klm
Lamp power factor

≥ 0,50 if P < 25 W

≥ 0,90 if P ≥ 25 W

≥ 0,55 if P < 25 W

≥ 0,90 if P ≥ 25 W

Colour rendering (Ra)≥ 80≥ 80

[F1Table 5

Functionality requirements for lamps excluding compact fluorescent lamps and LED lamps

Functionality parameter Stage 1 Stage 5
Rated lamp lifetime 1 000 h 2 000 h
Lumen maintenance ≥ 85 % at 75 % of rated average lifetime ≥ 85 % at 75 % of rated average lifetime
Number of switching cycles ≥ four times the rated lamp life expressed in hours ≥ four times the rated lamp life expressed in hours
Starting time < 0,2 s < 0,2 s
Lamp warm-up time to 60 % Φ ≤ 1,0 s ≤ 1,0 s
Premature failure rate ≤ 5,0 % at 100 h ≤ 5,0 % at 200 h
Lamp power factor ≥ 0,95 ≥ 0,95]

3.PRODUCT INFORMATION REQUIREMENTS ON LAMPSU.K.

For non-directional household lamps, the following information shall be provided as from Stage 2, except where otherwise stipulated.

3.1.Information to be visibly displayed prior to purchase to end-users on the packaging and on free access websitesU.K.

The information does not need to be specified using the exact wording of the list below. It may be displayed using graphs, figures or symbols rather than text.

These information requirements do not apply to filament lamps not fulfilling the efficacy requirements of Stage 4.

(a)

When the nominal lamp power is displayed outside the energy label in accordance with Directive 98/11/EC, the nominal luminous flux of the lamp shall also be separately displayed in a font at least twice as large as the nominal lamp power display outside the label;

(b)

Nominal life time of the lamp in hours (not higher than the rated life time);

(c)

Number of switching cycles before premature lamp failure;

(d)

Colour temperature (also expressed as a value in Kelvins);

(e)

Warm-up time up to 60 % of the full light output (may be indicated as ‘instant full light’ if less than 1 second);

(f)

A warning if the lamp cannot be dimmed or can be dimmed only on specific dimmers;

(g)

If designed for optimal use in non-standard conditions (such as ambient temperature Ta ≠ 25 °C), information on those conditions;

(h)

Lamp dimensions in millimeters (length and diameter);

(i)

If equivalence with an incandescent lamp is claimed on the packaging, the claimed equivalent incandescent lamp power (rounded to 1 W) shall be that corresponding in Table 6 to the luminous flux of the lamp contained in the packaging.

The intermediate values of both the luminous flux and the claimed incandescent lamp power (rounded to 1W) shall be calculated by linear interpolation between the two adjacent values.

Table 6
Rated lamp luminous fluxΦ [lm]Claimed equivalent incandescent lamp power
CFLHalogenLED and other lamps[W]
12511913615
22921724925
43241047040
74170280660
9709201 05575
1 3981 3261 521100
2 2532 1372 452150
3 1723 0093 452200
(j)

The term ‘energy saving lamp’ or any similar product related promotional statement about lamp efficacy may only be used if the lamp complies with the efficacy requirements applicable to non-clear lamps in Stage 1 according to Tables 1, 2 and 3.

If the lamp contains mercuryU.K.
(k)

Lamp mercury content as X,X mg;

(l)

Indication which website to consult in case of accidental lamp breakage to find instructions on how to clean up the lamp debris.

3.2.Information to be made publicly available on free-access websitesU.K.

As a minimum, the following information shall be expressed at least as values.

(a)

The information specified in point 3.1;

(b)

Rated wattage (0,1 W precision);

(c)

Rated luminous flux;

(d)

Rated lamp life time;

(e)

Lamp power factor;

(f)

Lumen maintenance factor at the end of the nominal life;

(g)

Starting time (as X,X seconds);

(h)

Colour rendering.

If the lamp contains mercuryU.K.
(i)

Instructions on how to clean up the lamp debris in case of accidental lamp breakage;

(j)

Recommendations on how to dispose of the lamp at its end of life.