xmlns:atom="http://www.w3.org/2005/Atom" xmlns:atom="http://www.w3.org/2005/Atom"

ANNEXU.K.

PART DU.K.REPORTING AND INTERPRETATION OF RESULTS

D.1.REPORTINGU.K.

D.1.1.Expression of resultsU.K.

The results shall be expressed in the same units and with the same number of significant figures as the maximum levels laid down in Regulation (EC) No 1881/2006.

D.1.2.Recovery calculationsU.K.

If an extraction step is applied in the analytical method, the analytical result shall be corrected for recovery. In this case the level of recovery must be reported.

[F1In case no extraction step is applied in the analytical method (e.g. in case of metals), the result may be reported uncorrected for recovery if evidence is provided by ideally making use of suitable certified reference material that the certified concentration allowing for the measurement uncertainty is achieved (i.e. high accuracy of the measurement), and thus that the method is not biased. In case the result is reported uncorrected for recovery this shall be mentioned.]

D.1.3.Measurement uncertaintyU.K.

The analytical result shall be reported as x +/– U whereby x is the analytical result and U is the expanded measurement uncertainty, using a coverage factor of 2 which gives a level of confidence of approximately 95 % (U = 2u).

[F1The analyst shall note the Report on the relationship between analytical results, measurement uncertainty, recovery factors and the provisions of EU food and feed legislation’(1) .]

D.2.INTERPRETATION OF RESULTSU.K.

D.2.1.Acceptance of a lot/sublotU.K.

The lot or sublot is accepted if the analytical result of the laboratory sample does not exceed the respective maximum level as laid down in Regulation (EC) No 1881/2006 taking into account the expanded measurement uncertainty and correction of the result for recovery if an extraction step has been applied in the analytical method used.

D.2.2.Rejection of a lot/sublotU.K.

The lot or sublot is rejected if the analytical result of the laboratory sample exceeds beyond reasonable doubt the respective maximum level as laid down in Regulation (EC) No 1881/2006 taking into account the expanded measurement uncertainty and correction of the result for recovery if an extraction step has been applied in the analytical method used.

D.2.3.ApplicabilityU.K.

The present interpretation rules shall apply for the analytical result obtained on the sample for enforcement. In case of analysis for defence or reference purposes, the national rules shall apply.