F1F2ANNEX I BREQUIREMENTS FOR CONSTRUCTION, TESTING, INSTALLATION AND INSPECTION

Annotations:
Appendix 6EXTERNAL INTERFACES

1.HARDWARE

1.2.Contact allocation

[INT_002] Contacts shall be allocated in accordance with the following table:

Pin

Description

Remark

1

Battery minus

Connected to the battery minus of the vehicle

2

Data communication

K-line (ISO 14 230-1)

3

RxD — Downloading

Data input to recording equipment

4

Input/output signal

Calibration

5

Permanent power output

The voltage range is specified to be that of the vehicle power minus 3V to allow for the voltage drop across the protective circuitry

Output 40 mA

6

TxD — Downloading

Data output from recording equipment