The ‘CE’ marking shall consist of the initials ‘CE’ in the following form:
If the ‘CE’ marking is reduced or enlarged the proportions given in the graduated drawing set out in this point must be respected.
The various components of the ‘CE’ marking must have substantially the same vertical dimension, which may not be less than 5 mm.
The vessel or data plate must bear at least the following information:
the maximum working pressure (PS in bar);
the maximum working temperature (Tmax in °C);
the minimum working temperature (Tmin in °C);
the capacity of the vessel (V in l);
the name or mark of the manufacturer;
the type and serial or batch identification of the vessel;
the last two digits of the year in which the ‘CE’ marking was affixed.
Where the data plate is used, it must be so designed that it cannot be reused and must include a vacant space to enable other information to be provided.