Article 1
Directive 2000/14/EC is hereby amended as follows:
- 1.
The table in Article 12 shall be replaced by the following:
‘Type of equipment
Net installed power P (in kW)Electric power Pel5 in kWMass of appliance m in kgCutting width L in cmPermissible sound power level in dB/1 pW
Stage I as from 3 January 2002
Stage II as from 3 January 2006
Compaction machines (vibrating rollers, vibratory plates, vibratory rammers)
P ≤ 8
108
10568 < P ≤ 70
109
1066
P> 70
89 + 11 lg P
86 + 11 lg P6
Tracked dozers, tracked loaders, tracked excavator-loaders
P ≤ 55
106
1036
P> 55
87 + 11 lg P
84 + 11 lg P6
Wheeled dozers, wheeled loaders, wheeled excavator-loaders, dumpers, graders, loader-type landfill compactors, combustion-engine driven counterbalanced lift trucks, mobile cranes, compaction machines (non-vibrating rollers), paver-finishers, hydraulic power packs
P ≤ 55
104
P> 55
85 + 11 lg P
Excavators, builders’ hoists for the transport of goods, construction winches, motor hoes
P ≤ 15
96
93
P> 15
83 + 11 lg P
80 + 11 lg P
Hand-held concrete-breakers and picks
m ≤ 15
107
105
15 <m< 30
94 + 11 lg m
92 + 11 lg m6
m ≥ 30
96 + 11 lg m
94 + 11 lg m
Tower cranes
98 + lg P
96 + lg P
Welding and power generators
Pel ≤ 2
97 + lg Pel
95 + lg Pel
2 <Pel ≤ 10
98 + lg Pel
96 + lg Pel
X1P el > 10
97 + lg Pel
95 + lg Pel
Compressors
P ≤ 15
99
97
P> 15
97 + 2 lg P
95 + 2 lg P
Lawnmowers, lawn trimmers/lawn-edge trimmers
L ≤50
96
946
50 <L ≤ 70
100
98
70 <L ≤ 120
100
986
L> 120
105
1036
The permissible sound power level shall be rounded up or down to the nearest integer number (less than 0,5, use lower number; greater than or equal to 0,5, use higher number)’
- 2.
Article 20 shall be amended as follows:
- (a)
In the first sentence of paragraph 1, the words ‘Not later than 3 January 2005’ shall be replaced by ‘Not later than 3 January 2007’;
- (b)
Paragraph 3 shall be deleted.
- (a)