The guaranteed sound power level of equipment listed below shall not exceed the permissible sound power level as laid down in the following tables of limit values:
builders' hoists for the transport of goods (combustion-engine driven)
Annex I, item 3. Measurement: Annex III, Part B, item 3U.K.
compaction machines (only vibrating and non-vibrating rollers, vibratory plates and vibratory rammers)
Annex I, item 8. Measurement: Annex III, Part B, item 8U.K.
compressors (< 350 kW)
Annex I, item 9. Measurement: Annex III, Part B, item 9U.K.
concrete-breakers and picks, hand-held
Annex I, item 10. Measurement: Annex III, Part B, item 10U.K.
construction winches (combustion-engine driven)
Annex I, item 12. Measurement: Annex III, Part B, item 12U.K.
dozers (< 500 kW)
Annex I, item 16. Measurement: Annex III, Part B, item 16U.K.
dumpers (< 500 kW)
Annex I, item 18. Measurement: Annex III, Part B, item 18U.K.
excavators, hydraulic or rope-operated (< 500 kW)
Annex I, item 20. Measurement: Annex III, Part B, item 20U.K.
excavator-loaders (< 500 kW)
Annex I, item 21. Measurement: Annex III, Part B, item 21U.K.
graders (< 500 kW)
Annex I, item 23. Measurement: Annex III, Part B, item 23U.K.
hydraulic power packs
Annex I, item 29. Measurement: Annex III, Part B, item 29U.K.
landfill compactors, loader-type with bucket (< 500 kW)
Annex I, item 31. Measurement: Annex III, Part B, item 31U.K.
lawnmowers (excluding agricultural and forestry equipment, and multi-purpose devices, the main motorised component of which has an installed power of more than 20 kW))
Annex I, item 32. Measurement: Annex III, Part B, item 32U.K.
lawn trimmers/lawn edge trimmers
Annex I, item 33; Measurement: Annex III, Part B, item 33U.K.
lift trucks, combustion-engine driven, counterbalanced (excluding ‘other counterbalanced lift trucks’ as defined in Annex I, item 36, second indent with a rated capacity of not more than 10 tonnes)
Annex I, item 36. Measurement: Annex III, Part B, item 36U.K.
loaders (< 500 kW)
Annex I, item 37. Measurement: Annex III, Part B, item 37U.K.
mobile cranes
Annex I, item 38. Measurement: Annex III, Part B, item 38U.K.
motor hoes (< 3 kW)
Annex I, item 40. Measurement: Annex III, Part B, item 40U.K.
paver-finishers (excluding paver-finishers equipped with a high-compaction screed)
Annex I, item 41. Measurement: Annex III, Part B, item 41U.K.
power generators (< 400 kW)
Annex I, item 45. Measurement: Annex III, Part B, item 45U.K.
tower cranes
Annex I, item 53. Measurement: Annex III, Part B, item 53U.K.
welding generators
Annex I, item 57. Measurement: Annex III, Part B, item 57.U.K.
| a P el for welding generators: conventional welding current multiplied by the conventional load voltage for the lowest value of the duty factor given by the manufacturer. P el for power generators: prime power according to ISO 8528-1:1993, clause 13.3.2 | |||
| b The figures for stage II are merely indicative for the following types of equipment:
Definitive figures will depend on amendment of the Directive following the report required in Article 20(1). In the absence of any such amendment, the figures for stage I will continue to apply for stage II. | |||
| c For single-engine mobile cranes, the figures for stage I shall continue to apply until 3 January 2008 . After that date, stage II figures shall apply. | |||
| The permissible sound power level shall be rounded up or down to the nearest integer number (less than 0,5, use lower number; greater than or equal to 0,5, use higher number)] | |||
| [F1Type of equipment | Net installed power P (in kW) Electric power P el a in kW Mass of appliance m in kg Cutting width L in cm | Permissible sound power level in dB/1 pW | |
|---|---|---|---|
| Stage I as from 3 January 2002 | Stage II as from 3 January 2006 | ||
| Compaction machines (vibrating rollers, vibratory plates, vibratory rammers) | P ≤ 8 | 108 | 105 b |
| 8 < P ≤ 70 | 109 | 106 b | |
| P > 70 | 89 + 11 lg P | 86 + 11 lg P b | |
| Tracked dozers, tracked loaders, tracked excavator-loaders | P ≤ 55 | 106 | 103 b |
| P > 55 | 87 + 11 lg P | 84 + 11 lg P b | |
| Wheeled dozers, wheeled loaders, wheeled excavator-loaders, dumpers, graders, loader-type landfill compactors, combustion-engine driven counterbalanced lift trucks, mobile cranes, compaction machines (non-vibrating rollers), paver-finishers, hydraulic power packs | P ≤ 55 | 104 | 101 b c |
| P > 55 | 85 + 11 lg P | 82 + 11 lg P b c | |
| Excavators, builders’ hoists for the transport of goods, construction winches, motor hoes | P ≤ 15 | 96 | 93 |
| P > 15 | 83 + 11 lg P | 80 + 11 lg P | |
| Hand-held concrete-breakers and picks | m ≤ 15 | 107 | 105 |
| 15 < m < 30 | 94 + 11 lg m | 92 + 11 lg m b | |
| m ≥ 30 | 96 + 11 lg m | 94 + 11 lg m | |
| Tower cranes | 98 + lg P | 96 + lg P | |
| Welding and power generators | P el ≤ 2 | 97 + lg P el | 95 + lg P el |
| 2 < P el ≤ 10 | 98 + lg P el | 96 + lg P el | |
| [X1P el > 10] | 97 + lg P el | 95 + lg P el | |
| Compressors | P ≤ 15 | 99 | 97 |
| P > 15 | 97 + 2 lg P | 95 + 2 lg P | |
| Lawnmowers, lawn trimmers/lawn-edge trimmers | L ≤ 50 | 96 | 94 b |
| 50 < L ≤ 70 | 100 | 98 | |
| 70 < L ≤ 120 | 100 | 98 b | |
| L > 120 | 105 | 103 b | |
Editorial Information
X1 Substituted by Corrigendum to Directive 2005/88/EC of the European Parliament and of the Council of 14 December 2005 amending Directive 2000/14/EC on the approximation of the laws of the Member States relating to the noise emission in the environment by equipment for use outdoors (Official Journal of the European Union L 344 of 27 December 2005).
Textual Amendments