Article 12Equipment subject to noise limits

The guaranteed sound power level of equipment listed below shall not exceed the permissible sound power level as laid down in the following tables of limit values:

  • builders' hoists for the transport of goods (combustion-engine driven)

    Definition:

    Annex I, item 3. Measurement: Annex III, Part B, item 3

  • compaction machines (only vibrating and non-vibrating rollers, vibratory plates and vibratory rammers)

    Definition:

    Annex I, item 8. Measurement: Annex III, Part B, item 8

  • compressors (< 350 kW)

    Definition:

    Annex I, item 9. Measurement: Annex III, Part B, item 9

  • concrete-breakers and picks, hand-held

    Definition:

    Annex I, item 10. Measurement: Annex III, Part B, item 10

  • construction winches (combustion-engine driven)

    Definition:

    Annex I, item 12. Measurement: Annex III, Part B, item 12

  • dozers (< 500 kW)

    Definition:

    Annex I, item 16. Measurement: Annex III, Part B, item 16

  • dumpers (< 500 kW)

    Definition:

    Annex I, item 18. Measurement: Annex III, Part B, item 18

  • excavators, hydraulic or rope-operated (< 500 kW)

    Definition:

    Annex I, item 20. Measurement: Annex III, Part B, item 20

  • excavator-loaders (< 500 kW)

    Definition:

    Annex I, item 21. Measurement: Annex III, Part B, item 21

  • graders (< 500 kW)

    Definitie

    Annex I, item 23. Measurement: Annex III, Part B, item 23

  • hydraulic power packs

    Definition:

    Annex I, item 29. Measurement: Annex III, Part B, item 29

  • landfill compactors, loader-type with bucket (< 500 kW)

    Definition:

    Annex I, item 31. Measurement: Annex III, Part B, item 31

  • lawnmowers (excluding agricultural and forestry equipment, and multi-purpose devices, the main motorised component of which has an installed power of more than 20 kW))

    Definition:

    Annex I, item 32. Measurement: Annex III, Part B, item 32

  • lawn trimmers/lawn edge trimmers

    Definition:

    Annex I, item 33; Measurement: Annex III, Part B, item 33

  • lift trucks, combustion-engine driven, counterbalanced (excluding ‘other counterbalanced lift trucks’ as defined in Annex I, item 36, second indent with a rated capacity of not more than 10 tonnes)

    Definition:

    Annex I, item 36. Measurement: Annex III, Part B, item 36

  • loaders (< 500 kW)

    Definition:

    Annex I, item 37. Measurement: Annex III, Part B, item 37

  • mobile cranes

    Definition:

    Annex I, item 38. Measurement: Annex III, Part B, item 38

  • motor hoes (< 3 kW)

    Definition:

    Annex I, item 40. Measurement: Annex III, Part B, item 40

  • paver-finishers (excluding paver-finishers equipped with a high-compaction screed)

    Definition:

    Annex I, item 41. Measurement: Annex III, Part B, item 41

  • power generators (< 400 kW)

    Definition

    Annex I, item 45. Measurement: Annex III, Part B, item 45

  • tower cranes

    Definition:

    Annex I, item 53. Measurement: Annex III, Part B, item 53

  • welding generators

    Definition:

    Annex I, item 57. Measurement: Annex III, Part B, item 57.

Type of equipment

Net installed power P (in kW)Electric power P el 40 in kWMass of appliance m in kgCutting width L in cm

Permissible sound power level in dB/1 pW

Stage I as from 3 January 2002

Stage II as from 3 January 2006

Compaction machines (vibrating rollers, vibratory plates, vibratory rammers)

P ≤ 8

108

10541

8 < P ≤ 70

109

10641

P > 70

89 + 11 lg P

86 + 11 lg P 41

Tracked dozers, tracked loaders, tracked excavator-loaders

P ≤ 55

106

10341

P > 55

87 + 11 lg P

84 + 11 lg P 41

Wheeled dozers, wheeled loaders, wheeled excavator-loaders, dumpers, graders, loader-type landfill compactors, combustion-engine driven counterbalanced lift trucks, mobile cranes, compaction machines (non-vibrating rollers), paver-finishers, hydraulic power packs

P ≤ 55

104

1014142

P > 55

85 + 11 lg P

82 + 11 lg P 4142

Excavators, builders’ hoists for the transport of goods, construction winches, motor hoes

P ≤ 15

96

93

P > 15

83 + 11 lg P

80 + 11 lg P

Hand-held concrete-breakers and picks

m ≤ 15

107

105

15 < m < 30

94 + 11 lg m

92 + 11 lg m 41

m ≥ 30

96 + 11 lg m

94 + 11 lg m

Tower cranes

98 + lg P

96 + lg P

Welding and power generators

P el ≤ 2

97 + lg P el

95 + lg P el

2 < P el ≤ 10

98 + lg P el

96 + lg P el

X1P el > 10

97 + lg P el

95 + lg P el

Compressors

P ≤ 15

99

97

P > 15

97 + 2 lg P

95 + 2 lg P

Lawnmowers, lawn trimmers/lawn-edge trimmers

L ≤ 50

96

9441

50 < L ≤ 70

100

98

70 < L ≤ 120

100

9841

L > 120

105

10341

The permissible sound power level shall be rounded up or down to the nearest integer number (less than 0,5, use lower number; greater than or equal to 0,5, use higher number)

40

F1P el for welding generators: conventional welding current multiplied by the conventional load voltage for the lowest value of the duty factor given by the manufacturer.

P el for power generators: prime power according to ISO 8528-1:1993, clause 13.3.2

41

The figures for stage II are merely indicative for the following types of equipment:

  • walk-behind vibrating rollers;

  • vibratory plates (> 3kW);

  • vibratory rammers;

  • dozers (steel tracked);

  • loaders (steel tracked > 55 kW);

  • combustion-engine driven counterbalanced lift trucks;

  • compacting screed paver-finishers;

  • hand-held internal combustion-engine concrete-breakers and picks (15 < m < 30)

  • lawnmowers, lawn trimmers/lawn-edge trimmers.

Definitive figures will depend on amendment of the Directive following the report required in Article 20(1). In the absence of any such amendment, the figures for stage I will continue to apply for stage II.

42