ANNEX IIU.K.METHODS OF ANALYSIS RELATING TO THE COMPOSITION OF EDIBLE CASEINS AND CASEINATES

METHOD 6U.K.

DETERMINATION OF pH U.K.

1.SCOPE AND FIELD OF APPLICATIONU.K.

This method determines the pH of:

  • caseinates.

2.DEFINITIONU.K.

The pH of caseinates: the pH, at 20 oC, of an aqueous solution of caseinates, as determined by the method specified.

3.PRINCIPLEU.K.

The electrometric determination of pH of an aqueous solution of caseinate, using a pH meter.

4.REAGENTSU.K.

Any water used in the preparation of the reagents or in the Procedure (6) shall be recently distilled water that has been protected from carbon dioxide absorption.

4.1. Buffer solutions, for calibration of the pH meter (5.2)U.K.

Two standard buffer solutions with pH values at 20 oC which are known to the second decimal place and will bracket the pH value of the sample under test, for example phtalate buffer solution of pH approximately 4 and a borax buffer solution of pH approximately 9.

5.APPARATUSU.K.
5.1. Balance, accuracy 0,1 grams.U.K.
5.2. pH meter, minimum sensitivity 0,05 pH unit, with a suitably calibrated elecrode, e.g. glass electrode and a calomel or other reference electrode.U.K.
5.3. Thermometer, accuracy 0,5 oC.U.K.
5.4. Conical flask, capacity 100 ml, fitted with a ground glass stopper.U.K.
5.5. Beaker, capacity 50 ml.U.K.
5.6. Mixer U.K.
5.7. Beaker, for the mixer (5.6) of at least 250 ml capacity.U.K.
6.PROCEDUREU.K.
6.1. Preparation of the test sample U.K.

As described in Section 1.2 of the General Provisions.

6.2. Determination U.K.