ANNEX IIU.K.METHODS OF ANALYSIS RELATING TO THE COMPOSITION OF EDIBLE CASEINS AND CASEINATES

METHOD 1U.K.

DETERMINATION OF MOISTURE CONTENT U.K.

1.SCOPE AND FIELD OF APPLICATIONU.K.

This method determines the moisture content in:

  • acid caseins

  • rennet caseins

  • caseinates

2.DEFINITIONU.K.

The moisture content of caseins and caseinates: the loss of mass as determined by the method specified.

3.PRINCIPLEU.K.

The residual mass of a test portion is determined after drying at atmospheric pressure in an oven at 102 oC ± 1 oC to constant mass. The loss of mass is calculated as a percentage by mass of the sample.

4.APPARATUSU.K.
4.1. Analytical balance U.K.
4.2. Dishes, flat-bottomed and of material non-corrodible under the conditions of test e.g. nickel, aluminium, stainless steel or glass. The dishes must have lids which fit tightly but which can readily be removed. Suitable dimensions are: diameter 60 to 80 mm and depth about 25 mm.U.K.
4.3. Atmospheric pressure drying oven, well ventilated, thermostatically controlled with temperature regulation (at 102 oC ± 1 oC). The temperature should be uniform throughout the oven.U.K.
4.4. Desiccator, containing freshly activated silica gel with a water content indicator or an equivalent desiccant.U.K.
4.5. Suitable device for handling dishes, e.g. laboratory tongs.U.K.
5.PROCEDUREU.K.
5.1. Preparation of the test sample U.K.

As described in Section 1.2 of the General Provisions.

5.2. Preparation of the dish U.K.
5.2.1.Heat the uncovered dish and its lid (4.2) in the oven (4.3), controlled at 102 oC ± 1 oC, for at least one hour.U.K.
5.2.2.Place the lid on the dish, transfer the covered dish to the desiccator (4.4), allow to cool to the temperature of the balance room and weigh to the nearest 0,1 mg (m0).U.K.
5.3. Test portion U.K.

Place 3 to 5 grams of the test sample (5.1) into the dish, cover with the lid and weigh to the nearest 0,1 mg (m1).

5.4. Determination U.K.