The Annex to Decision 2000/367/EC is amended as follows:
in Section 3 ‘Products and systems for protecting load-bearing elements or parts of works’, the classification table that relates to ‘ceilings with no independent fire resistance’ is replaced by the following table:
| ‘Applies to | ceilings with no independent fire resistance |
| Standard(s) | EN 13501-2; prEN 13381-1 |
| Classification: expressed in the same terms as the load-bearing element being protected | |
| Notes | If also fulfilling the requirement with regard to the “semi-natural” fire, the symbol “sn” is added to the classification.’ |
in Section 3 ‘Products and systems for protecting load-bearing elements or parts of works’, the classification table that relates to ‘fire protective coatings, boards, renderings, claddings and screens’ is replaced by the following table:
| ‘Applies to | fire protective coatings, boards, renderings, claddings and screens |
| Standard(s) | EN 13501-2; prEN 13381-2 to 8 |
| Classification: expressed in the same terms as the load-bearing element being protected | |
| Notes | —’ |
in Section 4 ‘Non-load bearing elements or parts of works and products therefor’, the classification table that relates to ‘partitions (including those incorporating uninsulated portions)’ is replaced by the following table:
| a For cavity barriers this standard is complemented by EOTA TR 031.’ | ||||||||||
| ‘Applies to | partitions (including partitions incorporating uninsulated portions, and cavity barriers) | |||||||||
| Standard(s) | EN13501-2; EN 1364-1a; EN 1992-1-2; EN 1993-1-2; EN 1994-1-2; EN 1995-1-2; EN 1996-1-2; EN 1999-1-2 | |||||||||
| Classification: - | ||||||||||
| E | 20 | 30 | 60 | 90 | 120 | |||||
| EI | 15 | 20 | 30 | 45 | 60 | 90 | 120 | 180 | 240 | |
| EI-M | 30 | 60 | 90 | 120 | 180 | 240 | ||||
| EW | 20 | 30 | 60 | 90 | 120 | |||||
| Notes | — | |||||||||