    Desktop Computers      Integrated Desktop Computers      Notebook Computers      Workstations      Small-Scale Servers      Thin Clients    ,    Computer Servers (as defined in Version 1,0 Computer Server specification)      Handhelds, PDAs, and Smartphones    ,

  Category A: ≤ 148,0    Category B: ≤ 175,0    Category C: ≤ 209,0    Category D: ≤ 234,0  ,  Category A: ≤ 40,0    Category B: ≤ 53,0    Category C: ≤ 88,5  ,

  1 kWh (per GB over base)     Base Memory:     Categories A, B and C:    2 GB    Category D:    4 GB  ,0,4 kWh (per GB over 4),
  Categories A and B:    35 kWh (FB Width ≤ 128-bit)    50 kWh (FB Width &gt; 128-bit)    Categories C and D:    50 kWh (FB Width &gt; 128-bit)  ,  Category B:    3 kWh (FB Width &gt; 64-bit)  ,
25 kWh,3 kWh,
    Proxying refers to a computer that maintains Full Network Connectivity as defined in Section 1 of this specification. For a system to qualify under the proxying weightings above, it must meet a non-proprietary proxying standard that has been approved by the EPA and the European Commission as meeting the goals of ENERGY STAR. Such approval must be in place prior to submittal of product data for qualification. See Section 3.C, ‘Qualifying Computers with Power Management Capabilities’, for further information and testing requirements.    ,
(in %),


55,40,60,45,
5,30,10,30,
40,30,30,25,
   Note: Weightings are included in the PTEC formula, above.  ,
(in %),
35,
10,
55,

  Off Mode: ≤ 2,0 W    Idle State:    Category A: ≤ 50,0 W    Category B: ≤ 65,0 W  ,

  Wake On LAN (WOL)    (Applies only if computer is shipped with WOL enabled)  ,+ 0,7 W for Off,

  Off Mode: ≤ 2 W    Sleep Mode (if applicable): ≤ 2 W    Idle State:    Category A: ≤ 12,0 W    Category B: ≤ 15,0 W  ,

  Wake On LAN (WOL)    (Applies only if computer is shipped with WOL enabled)  ,  + 0,7 W for Sleep    + 0,7 W for Off  ,


Sleep Mode,Shipped with a Sleep mode which is set to activate within 30 minutes of user inactivity. Computers shall reduce the speed of any active 1 Gb/s Ethernet network links when transitioning to Sleep or Off.,Desktop Computers,   ,
Integrated Desktop Computers,   ,
Notebook Computers,   ,
Workstations,   ,
,,
Small-Scale Servers,   ,
Thin Clients,,
Display Sleep Mode,Shipped with the display’s Sleep mode set to activate within 15 minutes of user inactivity.,Desktop Computers,   ,
Integrated Desktop Computers,   ,
Notebook Computers,   ,
Workstations,   ,
,,
Small-Scale Servers (if computer display is present),   ,
Thin Clients,   ,

Wake on LAN (WOL),Computers with Ethernet capability shall have the ability to enable and disable WOL for Sleep mode.,Desktop Computers,   ,
Integrated Desktop Computers,   ,
Notebook Computers,   ,
Workstations,   ,
,,
Small-Scale Servers,   ,
Thin Clients (Only applies if software updates from the centrally managed network are conducted while the unit is in sleep or off mode. Thin Clients whose standard framework for upgrading client software does not require off-hours scheduling are exempt from the requirement.),   ,
  Applies to computers shipped through Enterprise Channels, only:    Computers with Ethernet capability must meet one of the following requirements:      be shipped with Wake On LAN (WOL) enabled from the Sleep mode when operating on AC power (i.e. notebooks may automatically disable WOL when disconnected from the mains); or      provide control to enable WOL that is sufficiently-accessible from both the client operating system user interface and over the network if computer is shipped to enterprise without WOL enabled.    ,Desktop Computers,   ,
Integrated Desktop Computers,   ,
Notebook Computers,   ,
Workstations,   ,
,,
Small-Scale Servers,   ,
Thin Clients (Only applies if software updates from the centrally managed network are conducted while the unit is in sleep or off mode. Thin Clients whose standard framework for upgrading client software does not require off-hours scheduling are exempt from the requirement.),   ,
,
Wake Management,  Applies to computers shipped through Enterprise Channels, only:    Computers with Ethernet capability shall be capable of both remote (via network) and scheduled wake events from Sleep mode (e.g. Real Time Clock).    Manufacturers shall ensure, where the manufacturer has control (i.e. configured through hardware settings rather than software settings), that these settings can be managed centrally, as the client wishes, with tools provided by the manufacturer.  ,Desktop Computers,   ,
Integrated Desktop Computers,   ,
Notebook Computers,   ,
Workstations,   ,
,,
Small-Scale Servers,   ,
Thin Clients,   ,
,

All Computers,Power Supply Efficiency,  IPS: Generalised Internal Power Supply Efficiency Test Protocol Rev. 6.4.2    EPS: ENERGY STAR Test Method for External Power Supplies      Note: Should any information/procedures in addition to those described by the Internal Power Supply Efficiency Protocol be required in order to test an Internal Power Supply, partners must make available to EPA or the European Commission, as appropriate, upon request, the test setup used to acquire IPS data used in a product submittal.   ,  IPS: www.efficientpowersupplies.org    EPS: www.energystar.gov/powersupplies  ,
Desktop, Integrated, and Notebook Computers,E TEC (from measurements of Off Mode, Sleep Mode, and Idle State),ENERGY STAR Computer Test Method (Version 5,0), Annex I, Section III,Appendix A,
Workstations,P TEC (from measurements of Off Mode, Sleep Mode, Idle State, and Maximum Power),ENERGY STAR Computer Test Method (Version 5,0), Annex I, Section III-IV,
Small-Scale Servers,Off Mode and Idle State,ENERGY STAR Computer Test Method (Version 5,0), Annex I, Section III,
Thin Clients,Off Mode, Sleep Mode, and Idle State,ENERGY STAR Computer Test Method (Version 5,0), Annex I, Section III,
  (Reference IEC 62301: Household Electrical Appliances — Measurement of Standby Power, Sections 4.2, 4.3, 4.4).  ,
Supply Voltage,North America/Taiwan:,115 (± 1 %) Volts AC, 60 Hz (± 1 %),
Europe/Australia/New Zealand:,230 (± 1 %) Volts AC, 50 Hz (± 1 %),
Japan:,  100 (± 1 %) Volts AC, 50 Hz (± 1 %)/60 Hz (± 1 %)      Note: For products rated for &gt; 1,5 kW maximum power, the voltage range is ± 4 %   ,
Total Harmonic Distortion (THD) (Voltage),&lt; 2 % THD (&lt; 5 % for products which are rated for &gt; 1,5 kW maximum power),
Ambient Temperature,23 °C ± 5 °C,
Relative Humidity,10-80 %,
Linpack,http://www.netlib.org/linpack/,
SPECviewperf®,http://www.spec.org/benchmarks.html#gpc,
(in %),
60,
10,
30,
(in kWh),

Category A,40,
Category B,53,
Category C,88,5,
(in %),
35,
10,
55,