     Mounted without an air gap directly against class A1 or A2-s1, d0 products with minimum density 10 kg/m   3   or at least class D-s2, d2 products with minimum density 400 kg/m   3   .     ,
     A substrate of cellulose insulation material of at least class E may be included if mounted directly against the wood-based panel, but not for floorings.     ,
     Mounted with an air gap behind. The reverse face of the cavity shall be at least class A2-s1, d0 products with minimum density 10 kg/m   3   .     ,
     Mounted with an air gap behind. The reverse face of the cavity shall be at least class D-s2, d2 products with minimum density 400 kg/m   3   .     ,
     Veneered, phenol- and melamine-faced panels are included for class excl. floorings.     ,
     A vapour barrier with a thickness up to 0,4 mm and a mass up to 200 g/m   2   can be mounted in between the wood-based panel and a substrate if there are no air gaps in between.     ,
     Class as provided for in Table 1 of the Annex to Decision 2000/147/EC.     ,
     Class as provided for in Table 2 of the Annex to Decision 2000/147/EC.     ,

 Cement-bonded particleboard  , EN 634-2 , without an air gap behind the panel , 1 000 , 10 , B-s1, d0 , B   fl   -s1 ,
 Fibreboard, hard  , EN 622-2 , without an air gap behind the wood-based panel , 900 , 6 , D-s2, d0 , D   fl   -s1 ,
 Fibreboard, hard  , EN 622-2 , with a closed air gap not more than 22 mm behind the wood-based panel , 900 , 6 , D-s2, d2 , — ,
 Particleboard   ,   ,  , EN 312 , without an air gap behind the wood-based panel , 600 , 9 , D-s2, d0 , D   fl   -s1 ,
 Fibreboard, hard and medium   ,   ,  ,   EN 622-2      EN 622-3   ,
 MDF   ,   ,  , EN 622-5 ,
 MDF   ,   ,  , EN 300 ,
 Plywood   ,   ,  , EN 636 , -“- , 400 , 9 , D-s2, d0 , D   fl   -s1 ,
 Solid wood panel   ,   ,  , EN 13353 , 12 ,
 Flaxboard   ,   ,  , EN 15197 , -“- , 450 , 15 , D-s2, d0 , D   fl   -s1 ,
 Particleboard   ,  , EN 312 , with a closed or an open air gap not more than 22 mm behind the wood-based panel , 600 , 9 , D-s2, d2 , — ,
 Fibreboard, hard and medium   ,  ,   EN 622-2      EN 622-3   ,
 MDF   ,  , EN 622-5 ,
 OSB   ,  , EN 300 ,
 Plywood   ,  , EN 636 , -“- , 400 , 9 , D-s2, d2 , — ,
 Solid wood panel   ,  , EN 13353 , 12 ,
 Particleboard   ,  , EN 312 , with a closed air gap behind the wood-based panel , 600 , 15 , D-s2, d0 , D   fl   -s1 ,
 Fibreboard, medium   ,  , EN 622-3 ,
 MDF   ,  , EN 622-5 ,
 OSB   ,  , EN 300 ,
 Plywood   ,  , EN 636 , -“- , 400 , 15 , D-s2, d1 , D   fl   -s1 ,
 Solid wood panel   ,  , EN 13353 , D-s2, d0 ,
 Flaxboard   ,  , EN 15197 , -“- , 450 , 15 , D-s2, d0 , D   fl   -s1 ,
 Particleboard   ,  , EN 312 , with an open air gap behind the wood-based panel , 600 , 18 , D-s2, d0 , D   fl   -s1 ,
 Fibreboard, medium   ,  , EN 622-3 ,
 MDF   ,  , EN 622-5 ,
 OSB   ,  , EN 300 ,
 Plywood   ,  , EN 636 , -“- , 400 , 18 , D-s2, d0 , D   fl   -s1 ,
 Solid wood panel   ,  , EN 13353 ,
 Flaxboard   ,  , EN 15197 , -“- , 450 , 18 , D-s2, d0 , D   fl   -s1 ,
 Particleboard  , EN 312 , any , 600 , 3 , E , E   fl  ,
 OSB  , EN 300 ,
 MDF  , EN 622-5 , -“- , 400 , 3 , E , E   fl  ,
 250 , 9 , E , E   fl  ,
 Plywood  , EN 636 , -“- , 400 , 3 , E , E   fl  ,
 Fibreboard, hard  , EN 622-2 , -“- , 900 , 3 , E , E   fl  ,
 Fibreboard, medium  , EN 622-3 , -“- , 400 , 9 , E , E   fl  ,
 Fibreboard, soft , EN 622-4 , -“- , 250 , 9 , E , E   fl  ,
      Determined according to EN ISO 536 and with no more than 5 % organic additive content.      ,
      Classes as provided for in Table 1 of the Annex to Commission Decision 2000/147/EC.      ,


  Conforming to EN 520 (except perforated boards)  ,  ≥ 6,5 &lt; 9,5  ,  ≥ 800  ,  A1  ,  ≤ 220  ,  Any wood-based product with density ≥ 400 kg/m     3     or any product of at least class A2-s1, d0  ,  A2-s1, d0  ,
  &gt; 220 ≤ 320  ,  B-s1, d0  ,
  ≥ 9,5  ,  ≥ 600  ,  ≤ 220  ,  Any wood-based product with density ≥ 400 kg/m     3     or any product of at least class A2-s1, d0 or any insulating product of at least class E-d2 mounted according to method 1  ,  A2-s1, d0  ,
  &gt; 220 ≤ 320  ,  B-s1, d0  ,
     Either directly fixed (i.e. with no air gap) to a material having a reaction to fire of A2-s1, d0 or better and a density of at least 600 kg/m   3   , or mounted on a timber or metal batten support frame, with a non-ventilated (i.e. void open only at the top) air gap of at least 30 mm, the reverse face of the cavity so formed having a reaction to fire classification of A2-s1, d0 or better.     ,
     Classes as provided for in Table 1 of the Annex to Decision 2000/147/EC.     ,
     Complying with European Standard EN 438-7.     ,

 Interior grade non-FR Compact HPL panels  , Compact HPL meeting EN 438-4 type CGS , 1 350 , 6 , D-s2, d0 ,
 Interior grade non-FR HPL composite panels with wood-based substrates  , Composite panels comprising non-FR grade HPL meeting the requirements of EN 438-3, adhesively bonded to both sides of non-FR grade wood-based core of minimum thickness 12 mm complying with EN 13986, using PVAc or thermosetting adhesive at an application rate of 60 to 120 g/m   2  ,   Wood-based core minimum density 600      HPL minimum density  1 350   , 12 mm wood-based core with HPL ≥ 0,5 mm bonded to both sides , D-s2, d0 ,
     Applies to all species covered by the product standards.     ,
     Classes as provided for in Table 1 of the Annex to Decision 2000/147/EC.     ,
     Conditioned according to EN 13238.     ,

 Visual and machine graded structural timber with rectangular cross-sections shaped by sawing, planing or other methods or with round cross-sections , 350 , 22 , D-s2, d0 ,