Article 6U.K.Interpretation of results

1.The result of an analysis shall be considered non-compliant if the decision limit of the confirmatory method for the analyte is exceeded.

2.If a permitted limit has been established for a substance, the decision limit is the concentration above which it can be decided with a statistical certainty of 1 - ɑ that the permitted limit has been truly exceeded.

3.If no permitted limit has been established for a substance, the decision limit is the lowest concentration level at which a method can discriminate with a statistical certainty of 1 - ɑ that the particular analyte is present.

4.For substances listed in Group A of Annex I to Directive 96/23/EC, the ɑ error shall be 1 % or lower. For all other substances, the ɑ error shall be 5 % or lower.