<Legislation xmlns="http://www.legislation.gov.uk/namespaces/legislation" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" DocumentURI="http://www.legislation.gov.uk/eudn/2001/671" IdURI="http://www.legislation.gov.uk/id/eudn/2001/671" NumberOfProvisions="2" xsi:schemaLocation="http://www.legislation.gov.uk/namespaces/legislation http://www.legislation.gov.uk/schema/legislation.xsd" SchemaVersion="2.0" RestrictStartDate="2005-11-25" RestrictExtent="E+W+S+N.I."><ukm:Metadata xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:dct="http://purl.org/dc/terms/" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:ukm="http://www.legislation.gov.uk/namespaces/metadata">
					<dc:identifier>http://www.legislation.gov.uk/eudn/2001/671</dc:identifier><dc:title>Commission Decision of 21 August 2001 implementing Council Directive 89/106/EEC as regards the classification of the external fire performance of roofs and roof coverings (notified under document number C(2001) 2474) (Text with EEA relevance) (2001/671/EC)</dc:title><dc:description>Commission Decision of 21 August 2001 implementing Council Directive 89/106/EEC as regards the classification of the external fire performance of roofs and roof coverings (notified under document number C(2001) 2474) (Text with EEA relevance) (2001/671/EC)</dc:description><dc:modified>2021-02-17</dc:modified><dc:publisher>King's Printer of Acts of Parliament</dc:publisher><dc:source>https://webarchive.nationalarchives.gov.uk/eu-exit/https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=CELEX:02001D0671-20051125</dc:source><dc:type>text</dc:type><dc:format>text/xml</dc:format><dc:language>en</dc:language><dct:valid>2005-11-25</dct:valid>
					
					<atom:link rel="self" href="http://www.legislation.gov.uk/eudn/2001/671/data.xml" type="application/xml"/><atom:link rel="http://www.legislation.gov.uk/def/navigation/resources" href="http://www.legislation.gov.uk/eudn/2001/671/resources" title="More Resources"/>
					
					
					
					<atom:link rel="http://www.legislation.gov.uk/def/navigation/act" href="http://www.legislation.gov.uk/eudn/2001/671" title="whole act"/><atom:link rel="http://www.legislation.gov.uk/def/navigation/introduction" href="http://www.legislation.gov.uk/eudn/2001/671/introduction" title="introduction"/>
					<atom:link rel="http://www.legislation.gov.uk/def/navigation/body" href="http://www.legislation.gov.uk/eudn/2001/671/body" title="body"/>
					<atom:link rel="http://www.legislation.gov.uk/def/navigation/annexes" href="http://www.legislation.gov.uk/eudn/2001/671/annexes" title="annexes"/>
					
					<atom:link rel="http://www.legislation.gov.uk/def/date/euexitday" href="http://www.legislation.gov.uk/eudn/2001/671/2020-01-31" title="2020-01-31"/><atom:link rel="http://www.legislation.gov.uk/def/date/euexitTransitionEnd" href="http://www.legislation.gov.uk/eudn/2001/671/2020-12-31" title="2020-12-31"/>					
					
					
					
					<atom:link rel="alternate" type="application/rdf+xml" href="http://www.legislation.gov.uk/eudn/2001/671/data.rdf" title="RDF/XML"/><atom:link rel="alternate" type="application/akn+xml" href="http://www.legislation.gov.uk/eudn/2001/671/data.akn" title="AKN"/><atom:link rel="alternate" type="application/xhtml+xml" href="http://www.legislation.gov.uk/eudn/2001/671/data.xht" title="HTML snippet"/><atom:link rel="alternate" type="text/html" href="http://www.legislation.gov.uk/eudn/2001/671/data.htm" title="Website (XHTML) Default View"/><atom:link rel="alternate" type="text/csv" href="http://www.legislation.gov.uk/eudn/2001/671/data.csv" title="CSV"/><atom:link rel="alternate" type="application/pdf" href="http://www.legislation.gov.uk/eudn/2001/671/data.pdf" title="PDF"/>
					<atom:link rel="alternate" type="application/akn+xhtml" href="http://www.legislation.gov.uk/eudn/2001/671/data.html" title="HTML5 snippet"/>

					<atom:link rel="alternate" href="http://www.legislation.gov.uk/eudn/2001/671/pdfs/eudn_20010671_adopted_en.pdf" type="application/pdf" title="Original PDF"/><atom:link rel="alternate" href="http://www.legislation.gov.uk/eudn/2001/671/pdfs/eudn_20010671_2005-11-25_en.pdf" type="application/pdf" title="Revised PDF"/>
					<atom:link rel="http://purl.org/dc/terms/tableOfContents" hreflang="en" href="http://www.legislation.gov.uk/eudn/2001/671/contents" title="Table of Contents"/>
					
					<atom:link rel="http://purl.org/dc/terms/hasVersion" href="http://www.legislation.gov.uk/eudn/2001/671/adopted" title="adopted"/><atom:link rel="http://purl.org/dc/terms/hasVersion" href="http://www.legislation.gov.uk/eudn/2001/671/2005-11-25" title="2005-11-25"/>
					
					
					<ukm:EUMetadata><ukm:DocumentClassification>
            <ukm:DocumentCategory Value="euretained"/>
            <ukm:DocumentMainType Value="EuropeanUnionDecision"/>
            <ukm:DocumentStatus Value="revised"/>
         </ukm:DocumentClassification><ukm:Year Value="2001"/><ukm:Number Value="671"/><ukm:EURLexIdentifiers>
            <ukm:Cellar Value="97c4a91f-a342-478b-b830-032bbfbf33e9"/>
            <ukm:CELEX Value="02001D0671-20051125"/>
            <ukm:ELI Value="dec:2001:671:2005-11-25"/>
         </ukm:EURLexIdentifiers><ukm:EnactmentDate Date="2001-08-21"/><ukm:EURLexModified Date="2016-06-30T21:18:34Z"/><ukm:EURLexExtracted Date="2018-05-21T03:22:33Z"/><ukm:XMLGenerated Date="2021-02-16T20:30:18Z"/><ukm:XMLImported Date="2021-02-17T07:38:22Z"/><ukm:CreatedBy Label="Provisional data" URI="http://publications.europa.eu/resource/authority/corporate-body/OP_DATPRO"/><ukm:EURLexMetadata>
            <WORK xmlns="">
               <URI>
                  <VALUE>http://publications.europa.eu/resource/cellar/97c4a91f-a342-478b-b830-032bbfbf33e9</VALUE>
                  <IDENTIFIER>97c4a91f-a342-478b-b830-032bbfbf33e9</IDENTIFIER>
                  <TYPE>cellar</TYPE>
               </URI>
               <SAMEAS>
                  <URI>
                     <VALUE>http://publications.europa.eu/resource/consolidation/2001D0671%2F20051125</VALUE>
                     <IDENTIFIER>2001D0671/20051125</IDENTIFIER>
                     <TYPE>consolidation</TYPE>
                  </URI>
               </SAMEAS>
               <SAMEAS>
                  <URI>
                     <VALUE>http://publications.europa.eu/resource/celex/02001D0671-20051125</VALUE>
                     <IDENTIFIER>02001D0671-20051125</IDENTIFIER>
                     <TYPE>celex</TYPE>
                  </URI>
               </SAMEAS>
               <SAMEAS>
                  <URI>
                     <VALUE>http://publications.europa.eu/resource/eli/dec/2001/671/2005-11-25</VALUE>
                     <IDENTIFIER>dec:2001:671:2005-11-25</IDENTIFIER>
                     <TYPE>eli</TYPE>
                  </URI>
               </SAMEAS>
               <LASTMODIFICATIONDATE type="date">
                  <VALUE>2016-06-30T23:18:34.916+02:00</VALUE>
                  <YEAR>2016</YEAR>
                  <MONTH>06</MONTH>
                  <DAY>30</DAY>
               </LASTMODIFICATIONDATE>
               <WORK_ID_DOCUMENT type="data">
                  <VALUE>celex:02001D0671-20051125</VALUE>
               </WORK_ID_DOCUMENT>
               <WORK_PART_OF_COLLECTION_DOCUMENT type="concept">
                  <URI>
                     <VALUE>http://publications.europa.eu/resource/authority/document-collection/CONSLEG</VALUE>
                     <IDENTIFIER>CONSLEG</IDENTIFIER>
                     <TYPE>document-collection</TYPE>
                  </URI>
                  <OP-CODE>CONSLEG</OP-CODE>
                  <IDENTIFIER>CONSLEG</IDENTIFIER>
                  <PREFLABEL>CONSLEG</PREFLABEL>
               </WORK_PART_OF_COLLECTION_DOCUMENT>
               <IDENTIFIER type="data">
                  <VALUE>consolidation:2001D0671/20051125</VALUE>
               </IDENTIFIER>
               <IDENTIFIER type="data">
                  <VALUE>02001D0671-20051125</VALUE>
               </IDENTIFIER>
               <RESOURCE_LEGAL_DATE_ENTRY-INTO-FORCE type="date">
                  <VALUE>2005-11-25</VALUE>
                  <YEAR>2005</YEAR>
                  <MONTH>11</MONTH>
                  <DAY>25</DAY>
               </RESOURCE_LEGAL_DATE_ENTRY-INTO-FORCE>
               <ID_CELEX type="data">
                  <VALUE>02001D0671-20051125</VALUE>
               </ID_CELEX>
               <RESOURCE_LEGAL_NUMBER_NATURAL_CELEX type="data">
                  <VALUE>0671</VALUE>
               </RESOURCE_LEGAL_NUMBER_NATURAL_CELEX>
               <ACT_CONSOLIDATED_DATE type="date">
                  <VALUE>2005-11-25</VALUE>
                  <YEAR>2005</YEAR>
                  <MONTH>11</MONTH>
                  <DAY>25</DAY>
               </ACT_CONSOLIDATED_DATE>
               <DATE type="date">
                  <VALUE>2006-02-09</VALUE>
                  <YEAR>2006</YEAR>
                  <MONTH>02</MONTH>
                  <DAY>09</DAY>
               </DATE>
               <IDENTIFIER type="data">
                  <VALUE>http://data.europa.eu/eli/dec/2001/671/2005-11-25</VALUE>
               </IDENTIFIER>
               <DATE type="date">
                  <VALUE>2005-11-25</VALUE>
                  <YEAR>2005</YEAR>
                  <MONTH>11</MONTH>
                  <DAY>25</DAY>
               </DATE>
               <DATE_CREATION_LEGACY type="date">
                  <VALUE>2006-02-09</VALUE>
                  <YEAR>2006</YEAR>
                  <MONTH>02</MONTH>
                  <DAY>09</DAY>
               </DATE_CREATION_LEGACY>
               <WORK_DATE_DOCUMENT type="date">
                  <VALUE>2005-11-25</VALUE>
                  <YEAR>2005</YEAR>
                  <MONTH>11</MONTH>
                  <DAY>25</DAY>
               </WORK_DATE_DOCUMENT>
               <RESOURCE_LEGAL_NUMBER_NATURAL type="data">
                  <VALUE>671</VALUE>
               </RESOURCE_LEGAL_NUMBER_NATURAL>
               <ACT_CONSOLIDATED_CONSOLIDATES_RESOURCE_LEGAL type="link">
                  <URI>
                     <VALUE>http://publications.europa.eu/resource/cellar/d6b96135-53da-4c52-9b11-b5b4989570c2</VALUE>
                     <IDENTIFIER>d6b96135-53da-4c52-9b11-b5b4989570c2</IDENTIFIER>
                     <TYPE>cellar</TYPE>
                  </URI>
                  <SAMEAS>
                     <URI>
                        <VALUE>http://publications.europa.eu/resource/oj/JOL_2005_307_R_0053_01</VALUE>
                        <IDENTIFIER>JOL_2005_307_R_0053_01</IDENTIFIER>
                        <TYPE>oj</TYPE>
                     </URI>
                  </SAMEAS>
                  <SAMEAS>
                     <URI>
                        <VALUE>http://publications.europa.eu/resource/eli/dec/2005/823/oj</VALUE>
                        <IDENTIFIER>dec:2005:823:oj</IDENTIFIER>
                        <TYPE>eli</TYPE>
                     </URI>
                  </SAMEAS>
                  <SAMEAS>
                     <URI>
                        <VALUE>http://publications.europa.eu/resource/celex/32005D0823</VALUE>
                        <IDENTIFIER>32005D0823</IDENTIFIER>
                        <TYPE>celex</TYPE>
                     </URI>
                  </SAMEAS>
               </ACT_CONSOLIDATED_CONSOLIDATES_RESOURCE_LEGAL>
               <RESOURCE_LEGAL_HAS_TYPE_ACT_CONCEPT_TYPE_ACT type="concept">
                  <URI>
                     <VALUE>http://publications.europa.eu/resource/authority/fd_030/VC</VALUE>
                     <IDENTIFIER>VC</IDENTIFIER>
                     <TYPE>fd_030</TYPE>
                  </URI>
                  <OP-CODE>VC</OP-CODE>
                  <IDENTIFIER>VC</IDENTIFIER>
                  <PREFLABEL>Consolidated text</PREFLABEL>
               </RESOURCE_LEGAL_HAS_TYPE_ACT_CONCEPT_TYPE_ACT>
               <WORK_PART_OF_COLLECTION_DOCUMENT type="concept">
                  <URI>
                     <VALUE>http://publications.europa.eu/resource/authority/document-collection/CELEX</VALUE>
                     <IDENTIFIER>CELEX</IDENTIFIER>
                     <TYPE>document-collection</TYPE>
                  </URI>
                  <OP-CODE>CELEX</OP-CODE>
                  <IDENTIFIER>CELEX</IDENTIFIER>
                  <PREFLABEL>CELEX</PREFLABEL>
               </WORK_PART_OF_COLLECTION_DOCUMENT>
               <RESOURCE_LEGAL_ELI type="data">
                  <VALUE>http://data.europa.eu/eli/dec/2001/671/2005-11-25</VALUE>
               </RESOURCE_LEGAL_ELI>
               <BASED_ON type="link">
                  <URI>
                     <VALUE>http://publications.europa.eu/resource/cellar/e966977a-b614-4b60-83e8-0b408cea6109</VALUE>
                     <IDENTIFIER>e966977a-b614-4b60-83e8-0b408cea6109</IDENTIFIER>
                     <TYPE>cellar</TYPE>
                  </URI>
                  <SAMEAS>
                     <URI>
                        <VALUE>http://publications.europa.eu/resource/oj/JOL_2001_235_R_0020_01</VALUE>
                        <IDENTIFIER>JOL_2001_235_R_0020_01</IDENTIFIER>
                        <TYPE>oj</TYPE>
                     </URI>
                  </SAMEAS>
                  <SAMEAS>
                     <URI>
                        <VALUE>http://publications.europa.eu/resource/eli/dec/2001/671/oj</VALUE>
                        <IDENTIFIER>dec:2001:671:oj</IDENTIFIER>
                        <TYPE>eli</TYPE>
                     </URI>
                  </SAMEAS>
                  <SAMEAS>
                     <URI>
                        <VALUE>http://publications.europa.eu/resource/celex/32001D0671</VALUE>
                        <IDENTIFIER>32001D0671</IDENTIFIER>
                        <TYPE>celex</TYPE>
                     </URI>
                  </SAMEAS>
               </BASED_ON>
               <WORK_HAS_RESOURCE-TYPE type="concept">
                  <URI>
                     <VALUE>http://publications.europa.eu/resource/authority/resource-type/CONS_TEXT</VALUE>
                     <IDENTIFIER>CONS_TEXT</IDENTIFIER>
                     <TYPE>resource-type</TYPE>
                  </URI>
                  <OP-CODE>CONS_TEXT</OP-CODE>
                  <IDENTIFIER>CONS_TEXT</IDENTIFIER>
                  <PREFLABEL>Consolidated text</PREFLABEL>
               </WORK_HAS_RESOURCE-TYPE>
               <ID_SECTOR type="data">
                  <VALUE>0</VALUE>
               </ID_SECTOR>
               <IDENTIFIER type="data">
                  <VALUE>474062</VALUE>
               </IDENTIFIER>
               <ELI type="data">
                  <VALUE>http://data.europa.eu/eli/dec/2001/671/2005-11-25</VALUE>
               </ELI>
               <DATE_DOCUMENT type="date">
                  <VALUE>2005-11-25</VALUE>
                  <YEAR>2005</YEAR>
                  <MONTH>11</MONTH>
                  <DAY>25</DAY>
               </DATE_DOCUMENT>
               <RESOURCE_LEGAL_ID_CELEX type="data">
                  <VALUE>02001D0671-20051125</VALUE>
               </RESOURCE_LEGAL_ID_CELEX>
               <RESOURCE_LEGAL_TYPE type="data">
                  <VALUE>D</VALUE>
               </RESOURCE_LEGAL_TYPE>
               <WORK_ID_DOCUMENT type="data">
                  <VALUE>consolidation:2001D0671/20051125</VALUE>
               </WORK_ID_DOCUMENT>
               <YEAR type="data">
                  <VALUE>2001</VALUE>
               </YEAR>
               <WORK_CREATED_BY_AGENT type="concept">
                  <URI>
                     <VALUE>http://publications.europa.eu/resource/authority/corporate-body/OP_DATPRO</VALUE>
                     <IDENTIFIER>OP_DATPRO</IDENTIFIER>
                     <TYPE>corporate-body</TYPE>
                  </URI>
                  <OP-CODE>OP_DATPRO</OP-CODE>
                  <IDENTIFIER>OP_DATPRO</IDENTIFIER>
                  <PREFLABEL>Provisional data</PREFLABEL>
                  <ANNOTATION>
                     <ERROR_MESSAGE>Data missing</ERROR_MESSAGE>
                     <QUALITY_ISSUE>DATMIS</QUALITY_ISSUE>
                     <BUILD_INFO>cdm:CDM_2.1.7  tdm:1523  xslt:3945 saxon:9.0.0.1J JVM:1.6.0_29 metaconvJar:1.2.0 builddate:19/08/2014 17:30:34</BUILD_INFO>
                  </ANNOTATION>
               </WORK_CREATED_BY_AGENT>
               <RESOURCE_LEGAL_INFORMATION_MISCELLANEOUS type="data">
                  <VALUE>LASTMODIN {32005D0823|http://publications.europa.eu/resource/celex/32005D0823}</VALUE>
               </RESOURCE_LEGAL_INFORMATION_MISCELLANEOUS>
               <ACT_CONSOLIDATED_CONSOLIDATES_RESOURCE_LEGAL type="link">
                  <URI>
                     <VALUE>http://publications.europa.eu/resource/cellar/e966977a-b614-4b60-83e8-0b408cea6109</VALUE>
                     <IDENTIFIER>e966977a-b614-4b60-83e8-0b408cea6109</IDENTIFIER>
                     <TYPE>cellar</TYPE>
                  </URI>
                  <SAMEAS>
                     <URI>
                        <VALUE>http://publications.europa.eu/resource/oj/JOL_2001_235_R_0020_01</VALUE>
                        <IDENTIFIER>JOL_2001_235_R_0020_01</IDENTIFIER>
                        <TYPE>oj</TYPE>
                     </URI>
                  </SAMEAS>
                  <SAMEAS>
                     <URI>
                        <VALUE>http://publications.europa.eu/resource/eli/dec/2001/671/oj</VALUE>
                        <IDENTIFIER>dec:2001:671:oj</IDENTIFIER>
                        <TYPE>eli</TYPE>
                     </URI>
                  </SAMEAS>
                  <SAMEAS>
                     <URI>
                        <VALUE>http://publications.europa.eu/resource/celex/32001D0671</VALUE>
                        <IDENTIFIER>32001D0671</IDENTIFIER>
                        <TYPE>celex</TYPE>
                     </URI>
                  </SAMEAS>
               </ACT_CONSOLIDATED_CONSOLIDATES_RESOURCE_LEGAL>
               <ACT_CONSOLIDATED_BASED_ON_RESOURCE_LEGAL type="link">
                  <URI>
                     <VALUE>http://publications.europa.eu/resource/cellar/e966977a-b614-4b60-83e8-0b408cea6109</VALUE>
                     <IDENTIFIER>e966977a-b614-4b60-83e8-0b408cea6109</IDENTIFIER>
                     <TYPE>cellar</TYPE>
                  </URI>
                  <SAMEAS>
                     <URI>
                        <VALUE>http://publications.europa.eu/resource/oj/JOL_2001_235_R_0020_01</VALUE>
                        <IDENTIFIER>JOL_2001_235_R_0020_01</IDENTIFIER>
                        <TYPE>oj</TYPE>
                     </URI>
                  </SAMEAS>
                  <SAMEAS>
                     <URI>
                        <VALUE>http://publications.europa.eu/resource/eli/dec/2001/671/oj</VALUE>
                        <IDENTIFIER>dec:2001:671:oj</IDENTIFIER>
                        <TYPE>eli</TYPE>
                     </URI>
                  </SAMEAS>
                  <SAMEAS>
                     <URI>
                        <VALUE>http://publications.europa.eu/resource/celex/32001D0671</VALUE>
                        <IDENTIFIER>32001D0671</IDENTIFIER>
                        <TYPE>celex</TYPE>
                     </URI>
                  </SAMEAS>
               </ACT_CONSOLIDATED_BASED_ON_RESOURCE_LEGAL>
               <IDENTIFIER type="data">
                  <VALUE>celex:02001D0671-20051125</VALUE>
               </IDENTIFIER>
               <CREATED_BY type="concept">
                  <URI>
                     <VALUE>http://publications.europa.eu/resource/authority/corporate-body/OP_DATPRO</VALUE>
                     <IDENTIFIER>OP_DATPRO</IDENTIFIER>
                     <TYPE>corporate-body</TYPE>
                  </URI>
                  <OP-CODE>OP_DATPRO</OP-CODE>
                  <IDENTIFIER>OP_DATPRO</IDENTIFIER>
                  <PREFLABEL>Provisional data</PREFLABEL>
               </CREATED_BY>
               <RESOURCE_LEGAL_YEAR type="data">
                  <VALUE>2001</VALUE>
               </RESOURCE_LEGAL_YEAR>
               <TYPE>cdm:work</TYPE>
               <TYPE>cdm:act_consolidated</TYPE>
               <TYPE>D</TYPE>
               <TYPE>cdm:resource_legal</TYPE>
            </WORK>
            <EXPRESSION xmlns="">
               <URI>
                  <VALUE>http://publications.europa.eu/resource/cellar/97c4a91f-a342-478b-b830-032bbfbf33e9.0006</VALUE>
                  <IDENTIFIER>97c4a91f-a342-478b-b830-032bbfbf33e9.0006</IDENTIFIER>
                  <TYPE>cellar</TYPE>
               </URI>
               <SAMEAS>
                  <URI>
                     <VALUE>http://publications.europa.eu/resource/consolidation/2001D0671%2F20051125.ENG</VALUE>
                     <IDENTIFIER>2001D0671/20051125.ENG</IDENTIFIER>
                     <TYPE>consolidation</TYPE>
                  </URI>
               </SAMEAS>
               <SAMEAS>
                  <URI>
                     <VALUE>http://publications.europa.eu/resource/celex/02001D0671-20051125.ENG</VALUE>
                     <IDENTIFIER>02001D0671-20051125.ENG</IDENTIFIER>
                     <TYPE>celex</TYPE>
                  </URI>
               </SAMEAS>
               <TITLE type="data">
                  <VALUE>CELEX1</VALUE>
               </TITLE>
               <LANG type="data">
                  <VALUE>en</VALUE>
               </LANG>
               <TITLE type="data">
                  <VALUE>Commission Decision of 21 August 2001 implementing Council Directive 89/106/EEC as regards the classification of the external fire performance of roofs and roof coverings (notified under document number C(2001) 2474) (Text with EEA relevance) (2001/671/EC) </VALUE>
               </TITLE>
               <EXPRESSION_TITLE type="data">
                  <VALUE>Commission Decision of 21 August 2001 implementing Council Directive 89/106/EEC as regards the classification of the external fire performance of roofs and roof coverings (notified under document number C(2001) 2474) (Text with EEA relevance) (2001/671/EC) </VALUE>
               </EXPRESSION_TITLE>
               <LANG type="data">
                  <VALUE>eng</VALUE>
               </LANG>
               <LASTMODIFICATIONDATE type="date">
                  <VALUE>2014-10-08T20:14:41.689+02:00</VALUE>
                  <YEAR>2014</YEAR>
                  <MONTH>10</MONTH>
                  <DAY>08</DAY>
               </LASTMODIFICATIONDATE>
               <EXPRESSION_USES_LANGUAGE type="concept">
                  <URI>
                     <VALUE>http://publications.europa.eu/resource/authority/language/ENG</VALUE>
                     <IDENTIFIER>ENG</IDENTIFIER>
                     <TYPE>language</TYPE>
                  </URI>
                  <OP-CODE>ENG</OP-CODE>
                  <IDENTIFIER>ENG</IDENTIFIER>
                  <PREFLABEL>English</PREFLABEL>
                  <ALTLABEL>English</ALTLABEL>
               </EXPRESSION_USES_LANGUAGE>
            </EXPRESSION>
         </ukm:EURLexMetadata><ukm:DocumentCurrentStatus><ukm:UKAmended Value="false"/></ukm:DocumentCurrentStatus></ukm:EUMetadata>
					

                    
									 
					<ukm:Alternatives><ukm:Alternative URI="http://www.legislation.gov.uk/eudn/2001/671/pdfs/eudn_20010671_adopted_en.pdf" Date="2001-08-21" Size="158398"/><ukm:Alternative URI="http://www.legislation.gov.uk/eudn/2001/671/pdfs/eudn_20010671_2005-11-25_en.pdf" Date="2005-11-25" Size="43397" Revised="2005-11-25"/> </ukm:Alternatives>
					
					<ukm:Statistics>
									<ukm:TotalParagraphs Value="9"/>
									<ukm:BodyParagraphs Value="2"/>
									<ukm:ScheduleParagraphs Value="7"/>
									<ukm:AttachmentParagraphs Value="0"/>
									<ukm:TotalImages Value="0"/>
								</ukm:Statistics>
				</ukm:Metadata><EURetained>
      <EUPrelims DocumentURI="http://www.legislation.gov.uk/eudn/2001/671/introduction" IdURI="http://www.legislation.gov.uk/id/eudn/2001/671/introduction" RestrictStartDate="2005-11-25" RestrictExtent="E+W+S+N.I.">
         <MultilineTitle>
            <Text>
               <Uppercase>Commission Decision</Uppercase>
            </Text>
            <Text>of 21 August 2001</Text>
            <Text>implementing Council Directive 89/106/EEC as regards the classification of the external fire performance of roofs and roof coverings</Text>
            <Text>(notified under document number C(2001) 2474)</Text>
            <Text>(Text with EEA relevance)</Text>
            <Text>(2001/671/EC)</Text>
         </MultilineTitle>
         <EUPreamble>
            <P>
               <Text>THE COMMISSION OF THE EUROPEAN COMMUNITIES,</Text>
            </P>
            <P>
               <Text>Having regard to the Treaty establishing the European Community,</Text>
            </P>
            <P>
               <Text>Having regard to Council Directive 89/106/EEC of 21 December 1988 on the approximation of the laws, regulations and administrative provisions of the Member States relating to construction products<FootnoteRef Ref="f00001"/>, as amended by Directive 93/68/EEC<FootnoteRef Ref="f00002"/>, and in particular Article 20(2)(a) thereof,</Text>
            </P>
            <P>
               <Text>Whereas:</Text>
            </P>
            <Division>
               <Number>(1)</Number>
               <P>
                  <Text>Article 3(2) of Directive 89/106/EEC states that in order to take account of different levels of protection for the construction works that may prevail at national, regional or local levels, each essential requirement may give rise to the establishment of classes in the interpretative documents. These documents have been published as the ‘Communication of the Commission with regard to the interpretative documents of Directive 89/106/EEC’<FootnoteRef Ref="f00003"/>.</Text>
               </P>
            </Division>
            <Division>
               <Number>(2)</Number>
               <P>
                  <Text>Paragraph 2.2 of interpretative document No 2 lists a number of interrelated measures for the satisfaction of the essential requirement ‘Safety in case of fire’ that together contribute to define the fire safety strategy that can be developed in different ways in Member States.</Text>
               </P>
            </Division>
            <Division>
               <Number>(3)</Number>
               <P>
                  <Text>Paragraph 4.2.1 of interpretative document No 2 justifies the need for different levels of the essential requirement as function of the type, use and location of the construction work, its layout and the availability of the emergency facilities.</Text>
               </P>
            </Division>
            <Division>
               <Number>(4)</Number>
               <P>
                  <Text>Paragraph 4.3.1.2.2 of interpretative document No 2 identifies the requirements for construction products for roofs exposed to an external fire.</Text>
               </P>
            </Division>
            <Division>
               <Number>(5)</Number>
               <P>
                  <Text>The different levels of these requirements existing in the Member States may be expressed in a system of classes that are not included in interpretative document No 2.</Text>
               </P>
            </Division>
            <Division>
               <Number>(6)</Number>
               <P>
                  <Text>Article 6(3) of Directive 89/106/EEC states that the Member States may determine the performance levels to be observed in their territory only within the classifications adopted at Community level and only subject to the use of all or some classes or one class.</Text>
               </P>
            </Division>
            <Division>
               <Number>(7)</Number>
               <P>
                  <Text>In the absence of a single, fully harmonised test method, the classification used in this Decision should be based upon one standard which incorporates three distinct test methods that respond to different fire hazard scenarios. This is considered to be an interim solution until full harmonisation can be achieved through the development of a fully harmonised test method. Once the latter is achieved, this Decision could be amended to take account of the new test method and its associated classifications.</Text>
               </P>
            </Division>
            <Division>
               <Number>(8)</Number>
               <P>
                  <Text>The measures provided for in this Decision are in accordance with the opinion of the Standing Committee on Construction,</Text>
               </P>
            </Division>
            <P>
               <Text>HAS ADOPTED THIS DECISION:</Text>
            </P>
         </EUPreamble>
      </EUPrelims>
      <EUBody DocumentURI="http://www.legislation.gov.uk/eudn/2001/671/body" IdURI="http://www.legislation.gov.uk/id/eudn/2001/671/body" NumberOfProvisions="2" RestrictStartDate="2005-11-25" RestrictExtent="E+W+S+N.I.">
         <P1 DocumentURI="http://www.legislation.gov.uk/eudn/2001/671/article/1" IdURI="http://www.legislation.gov.uk/id/eudn/2001/671/article/1" id="article-1" RestrictStartDate="2005-11-25" RestrictExtent="E+W+S+N.I.">
            <Pnumber>Article 1</Pnumber>
            <P1para>
               <Text>A Community classification system as envisaged by Directive 89/106/EEC is hereby established in respect of the external fire performance of roofs and roof coverings.</Text>
            </P1para>
            <P1para>
               <Text>That classification system shall be as set out in the Annex hereto.</Text>
            </P1para>
         </P1>
         <P1 DocumentURI="http://www.legislation.gov.uk/eudn/2001/671/article/2" IdURI="http://www.legislation.gov.uk/id/eudn/2001/671/article/2" id="article-2" RestrictStartDate="2005-11-25" RestrictExtent="E+W+S+N.I.">
            <Pnumber>Article 2</Pnumber>
            <P1para>
               <Text>This Decision is addressed to the Member States.</Text>
            </P1para>
         </P1>
      </EUBody>
      <Schedules RestrictStartDate="2005-11-25" RestrictExtent="E+W+S+N.I.">
         <Schedule DocumentURI="http://www.legislation.gov.uk/eudn/2001/671/annex" IdURI="http://www.legislation.gov.uk/id/eudn/2001/671/annex" id="annex" RestrictStartDate="2005-11-25" RestrictExtent="E+W+S+N.I.">
            <Number>ANNEX</Number>
            <ScheduleBody>
               <Division DocumentURI="http://www.legislation.gov.uk/eudn/2001/671/annex/division/1" IdURI="http://www.legislation.gov.uk/id/eudn/2001/671/annex/division/1" id="annex-division-1" RestrictStartDate="2005-11-25" RestrictExtent="E+W+S+N.I.">
                  <Title>PREAMBLE</Title>
                  <P>
                     <Text>
                        <Substitution ChangeId="O001001M001" CommentaryRef="c000001">ENV 1187:2002 and subsequently upgraded versions shall be applied. The upgraded version shall include, </Substitution>
                        <Emphasis>
                           <Substitution ChangeId="O001001M001" CommentaryRef="c000001">inter alia</Substitution>
                        </Emphasis>
                        <Substitution ChangeId="O001001M001" CommentaryRef="c000001">, new revisions/amendments of the ENV or the EN version of this standard.</Substitution>
                     </Text>
                  </P>
                  <P>
                     <Text>The classification set out in the table below is based upon the standard contained in <Substitution ChangeId="O001001M002" CommentaryRef="c000001">ENV 1187:2002</Substitution>. That standard incorporates <Substitution ChangeId="O001001M003" CommentaryRef="c000001">four</Substitution> distinct test methods that correspond to different fire hazard scenarios. There is no direct correlation between the test methods and hence no generally acceptable hierarchy of classification between them.</Text>
                  </P>
                  <P>
                     <Text>In regulating for the external fire performance of roofs/roof coverings, Member States may select the test/class combination(s) appropriate to the actual fire hazard(s) on their territory and establish a national hierarchy of classification between the various tests/classes.</Text>
                  </P>
                  <P>
                     <Text>Commission Decision 2000/553/EC<FootnoteRef Ref="f00004"/> establishes a list of roof covering products (and/or materials) which can be considered to fulfil all of the requirements for the performance characteristics ‘external fire performance’ without the need for testing, subject to any national provisions on the design and execution of works being fulfilled. Such products/materials are considered to be Classes B<Inferior>ROOF</Inferior> in the table below, without the need for testing.</Text>
                  </P>
               </Division>
               <Division DocumentURI="http://www.legislation.gov.uk/eudn/2001/671/annex/division/2" IdURI="http://www.legislation.gov.uk/id/eudn/2001/671/annex/division/2" id="annex-division-2" RestrictStartDate="2005-11-25" RestrictExtent="E+W+S+N.I.">
                  <Title>SYMBOLS</Title>
                  <P>
                     <Text>The classifications according to the <Substitution ChangeId="O001001M004" CommentaryRef="c000001">four</Substitution> test methods are identified as follows:</Text>
                  </P>
                  <P>
                     <UnorderedList Decoration="dash">
                        <ListItem>
                           <Para>
                              <Text>
                                 <Substitution ChangeId="O001001M005" CommentaryRef="c000001">ENV 1187:2002</Substitution> test 1: X<Inferior>ROOF</Inferior>(t1), where t1 = Burning brand alone,</Text>
                           </Para>
                        </ListItem>
                        <ListItem>
                           <Para>
                              <Text>
                                 <Substitution ChangeId="O001001M005" CommentaryRef="c000001">ENV 1187:2002</Substitution> test 2: X<Inferior>ROOF</Inferior>(t2), where t2 = Burning brand + wind,</Text>
                           </Para>
                        </ListItem>
                        <ListItem>
                           <Para>
                              <Text>
                                 <Substitution ChangeId="O001001M005" CommentaryRef="c000001">ENV 1187:2002</Substitution> test 3: X<Inferior>ROOF</Inferior>(t3), where t3 = Burning brand + wind + radiation<Substitution ChangeId="O001001M006" CommentaryRef="c000001">,</Substitution>
                              </Text>
                           </Para>
                        </ListItem>
                        <ListItem>
                           <Para>
                              <Text>
                                 <Addition ChangeId="O001001M007" CommentaryRef="c000002">ENV 1187:2002 test 4: X</Addition>
                                 <Inferior>
                                    <Addition ChangeId="O001001M007" CommentaryRef="c000002">ROOF</Addition>
                                 </Inferior>
                                 <Addition ChangeId="O001001M007" CommentaryRef="c000002"> (t4) where t4 = burning brand + wind + supplementary radiant heat.</Addition>
                              </Text>
                           </Para>
                        </ListItem>
                     </UnorderedList>
                  </P>
                  <P>
                     <KeyList Separator=":">
                        <KeyListItem>
                           <Key>T<Inferior>E</Inferior>
                           </Key>
                           <ListItem>
                              <Para>
                                 <Text>critical external fire spread time</Text>
                              </Para>
                           </ListItem>
                        </KeyListItem>
                        <KeyListItem>
                           <Key>T<Inferior>P</Inferior>
                           </Key>
                           <ListItem>
                              <Para>
                                 <Text>critical time to fire penetration</Text>
                              </Para>
                           </ListItem>
                        </KeyListItem>
                     </KeyList>
                  </P>
                  <Tabular Orientation="portrait">
                     <table xmlns="http://www.w3.org/1999/xhtml" cols="3">
                        <thead><tr><td colspan="3">Table</td></tr><tr><td colspan="3">CLASSES OF EXTERNAL FIRE PERFORMANCE FOR ROOFS/ROOF COVERINGS <FootnoteRef xmlns="http://www.legislation.gov.uk/namespaces/legislation" Ref="f00005"/>
                              </td></tr></thead>
                        <tfoot><tr><td colspan="3">
                                 <Footnote xmlns="http://www.legislation.gov.uk/namespaces/legislation" id="f00005">
                                    <FootnoteText>
                                       <Para>
                                          <Text>The number of classes is still under review and will be amended as soon as the necessary information is available.</Text>
                                       </Para>
                                    </FootnoteText>
                                 </Footnote>
                              </td></tr><tr><td colspan="3">
                                 <Addition xmlns="http://www.legislation.gov.uk/namespaces/legislation" ChangeId="O001001M008" CommentaryRef="c000002">*</Addition> 
                                 <Addition xmlns="http://www.legislation.gov.uk/namespaces/legislation" ChangeId="O001001M008" CommentaryRef="c000002">Attention shall be drawn to dripping from the underside of the specimen, any mechanical failure and any development of holes by adding a suffix </Addition>“<Addition xmlns="http://www.legislation.gov.uk/namespaces/legislation" ChangeId="O001001M008" CommentaryRef="c000002">x</Addition>”<Addition xmlns="http://www.legislation.gov.uk/namespaces/legislation" ChangeId="O001001M008" CommentaryRef="c000002"> to the designation to denote that one or more of these took place during the test. In addition, depending upon inclination of the product during the test, the letters EXT.F will be added to indicate </Addition>“<Addition xmlns="http://www.legislation.gov.uk/namespaces/legislation" ChangeId="O001001M008" CommentaryRef="c000002">flat or horizontal</Addition>”<Addition xmlns="http://www.legislation.gov.uk/namespaces/legislation" ChangeId="O001001M008" CommentaryRef="c000002"> and EXT.S will be added to indicate </Addition>“<Addition xmlns="http://www.legislation.gov.uk/namespaces/legislation" ChangeId="O001001M008" CommentaryRef="c000002">inclined</Addition>”<Addition xmlns="http://www.legislation.gov.uk/namespaces/legislation" ChangeId="O001001M008" CommentaryRef="c000002">.</Addition>
                              </td></tr></tfoot>
                        <tbody><tr><th>Test method</th><th>Class</th><th>Classification criteria</th></tr><tr><td rowspan="2">CR1187:2001 test 1</td><td>B<Inferior xmlns="http://www.legislation.gov.uk/namespaces/legislation">ROOF</Inferior> (t1)</td><td>
                                 <Para xmlns="http://www.legislation.gov.uk/namespaces/legislation">
                                    <Text>All of the following conditions must be satisfied:</Text>
                                 </Para>
                                 <UnorderedList xmlns="http://www.legislation.gov.uk/namespaces/legislation" Decoration="dash">
                                    <ListItem>
                                       <Para>
                                          <Text>external and internal fire spread upwards &lt; 0,700 m,</Text>
                                       </Para>
                                    </ListItem>
                                    <ListItem>
                                       <Para>
                                          <Text>external and internal fire spread downwards &lt; 0,600 m,</Text>
                                       </Para>
                                    </ListItem>
                                    <ListItem>
                                       <Para>
                                          <Text>maximum burned length external and internal &lt; 0,800 m,</Text>
                                       </Para>
                                    </ListItem>
                                    <ListItem>
                                       <Para>
                                          <Text>no burning material (droplets or debris) falling from exposed side,</Text>
                                       </Para>
                                    </ListItem>
                                    <ListItem>
                                       <Para>
                                          <Text>no burning/glowing particles penetrating the roof construction,</Text>
                                       </Para>
                                    </ListItem>
                                    <ListItem>
                                       <Para>
                                          <Text>no single through opening &gt; 2,5 × 10<Superior>–5</Superior> m<Superior>2</Superior>,</Text>
                                       </Para>
                                    </ListItem>
                                    <ListItem>
                                       <Para>
                                          <Text>sum of all through openings &lt; 4,5 × 10<Superior>–3</Superior> m<Superior>2</Superior>,</Text>
                                       </Para>
                                    </ListItem>
                                    <ListItem>
                                       <Para>
                                          <Text>lateral fire spread does not reach the edges of the measurement zone,</Text>
                                       </Para>
                                    </ListItem>
                                    <ListItem>
                                       <Para>
                                          <Text>no internal glowing combustion,</Text>
                                       </Para>
                                    </ListItem>
                                    <ListItem>
                                       <Para>
                                          <Text>maximum redius of fire spread on ‘horizontal’, roofs, external and internal &lt; 0,200 m.</Text>
                                       </Para>
                                    </ListItem>
                                 </UnorderedList>
                              </td></tr><tr><td>F<Inferior xmlns="http://www.legislation.gov.uk/namespaces/legislation">ROOF</Inferior> (t1)</td><td>No performance determined</td></tr><tr><td rowspan="2">CR1187:2001 test 2</td><td>B<Inferior xmlns="http://www.legislation.gov.uk/namespaces/legislation">ROOF</Inferior> (t2)</td><td>
                                 <Para xmlns="http://www.legislation.gov.uk/namespaces/legislation">
                                    <Text>For both test series at 2 m/s and 4 m/s wind speed:</Text>
                                 </Para>
                                 <UnorderedList xmlns="http://www.legislation.gov.uk/namespaces/legislation" Decoration="dash">
                                    <ListItem>
                                       <Para>
                                          <Text>mean damaged length of the roofing and underlay ≤ 0,550 m,</Text>
                                       </Para>
                                    </ListItem>
                                    <ListItem>
                                       <Para>
                                          <Text>maximum damaged length of the roofing and underlay ≤ 0,800 m,</Text>
                                       </Para>
                                    </ListItem>
                                 </UnorderedList>
                              </td></tr><tr><td>F<Inferior xmlns="http://www.legislation.gov.uk/namespaces/legislation">ROOF</Inferior> (t2)</td><td>No performance determined</td></tr><tr><td rowspan="4">CR1187:2001 test 3</td><td>B<Inferior xmlns="http://www.legislation.gov.uk/namespaces/legislation">ROOF</Inferior> (t3)</td><td>T<Inferior xmlns="http://www.legislation.gov.uk/namespaces/legislation">E</Inferior> ≥ 30 min and T<Inferior xmlns="http://www.legislation.gov.uk/namespaces/legislation">P</Inferior> ≥ 30 min</td></tr><tr><td>C<Inferior xmlns="http://www.legislation.gov.uk/namespaces/legislation">ROOF</Inferior> (t3)</td><td>T<Inferior xmlns="http://www.legislation.gov.uk/namespaces/legislation">E</Inferior> ≥ 10 min and T<Inferior xmlns="http://www.legislation.gov.uk/namespaces/legislation">P</Inferior> ≥ 15 min</td></tr><tr><td>D<Inferior xmlns="http://www.legislation.gov.uk/namespaces/legislation">ROOF</Inferior> (t3)</td><td>T<Inferior xmlns="http://www.legislation.gov.uk/namespaces/legislation">P</Inferior>&gt; 5 min</td></tr><tr><td>F<Inferior xmlns="http://www.legislation.gov.uk/namespaces/legislation">ROOF</Inferior> (t3)</td><td>No performance determined</td></tr><tr><td rowspan="5">
                                 <Addition xmlns="http://www.legislation.gov.uk/namespaces/legislation" ChangeId="O001001M009" CommentaryRef="c000002">ENV 1187:2002 test 4</Addition>
                              </td><td>
                                 <Addition xmlns="http://www.legislation.gov.uk/namespaces/legislation" ChangeId="O001001M009" CommentaryRef="c000002">B</Addition>
                                 <Inferior xmlns="http://www.legislation.gov.uk/namespaces/legislation">
                                    <Addition ChangeId="O001001M009" CommentaryRef="c000002">ROOF</Addition>
                                 </Inferior>
                                 <Addition xmlns="http://www.legislation.gov.uk/namespaces/legislation" ChangeId="O001001M009" CommentaryRef="c000002"> (t4)</Addition>
                              </td><td>
                                 <Para xmlns="http://www.legislation.gov.uk/namespaces/legislation">
                                    <Text>
                                       <Addition ChangeId="O001001M009" CommentaryRef="c000002">All of the following conditions must be satisfied:</Addition>
                                    </Text>
                                 </Para>
                                 <UnorderedList xmlns="http://www.legislation.gov.uk/namespaces/legislation" Decoration="dash">
                                    <ListItem>
                                       <Para>
                                          <Text>
                                             <Addition ChangeId="O001001M009" CommentaryRef="c000002">No penetration of roof system within 1 hour</Addition>
                                          </Text>
                                       </Para>
                                    </ListItem>
                                    <ListItem>
                                       <Para>
                                          <Text>
                                             <Addition ChangeId="O001001M009" CommentaryRef="c000002">In the preliminary test, after withdrawal of test flame, specimens burn for &lt; 5 minutes</Addition>
                                          </Text>
                                       </Para>
                                    </ListItem>
                                    <ListItem>
                                       <Para>
                                          <Text>
                                             <Addition ChangeId="O001001M009" CommentaryRef="c000002">In the preliminary test, flame spread &lt; 0.38 m across the region of burning</Addition>
                                          </Text>
                                       </Para>
                                    </ListItem>
                                 </UnorderedList>
                              </td></tr><tr><td>
                                 <Addition xmlns="http://www.legislation.gov.uk/namespaces/legislation" ChangeId="O001001M009" CommentaryRef="c000002">C</Addition>
                                 <Inferior xmlns="http://www.legislation.gov.uk/namespaces/legislation">
                                    <Addition ChangeId="O001001M009" CommentaryRef="c000002">ROOF</Addition>
                                 </Inferior>
                                 <Addition xmlns="http://www.legislation.gov.uk/namespaces/legislation" ChangeId="O001001M009" CommentaryRef="c000002"> (t4)</Addition>
                              </td><td>
                                 <Para xmlns="http://www.legislation.gov.uk/namespaces/legislation">
                                    <Text>
                                       <Addition ChangeId="O001001M009" CommentaryRef="c000002">All of the following conditions must be satisfied:</Addition>
                                    </Text>
                                 </Para>
                                 <UnorderedList xmlns="http://www.legislation.gov.uk/namespaces/legislation" Decoration="dash">
                                    <ListItem>
                                       <Para>
                                          <Text>
                                             <Addition ChangeId="O001001M009" CommentaryRef="c000002">No penetration of roof system within 30 minutes</Addition>
                                          </Text>
                                       </Para>
                                    </ListItem>
                                    <ListItem>
                                       <Para>
                                          <Text>
                                             <Addition ChangeId="O001001M009" CommentaryRef="c000002">In the preliminary test, after withdrawal of test flame, specimens burn for &lt; 5 minutes</Addition>
                                          </Text>
                                       </Para>
                                    </ListItem>
                                    <ListItem>
                                       <Para>
                                          <Text>
                                             <Addition ChangeId="O001001M009" CommentaryRef="c000002">In the preliminary test, flame spread &lt; 0.38 m across the region of burning</Addition>
                                          </Text>
                                       </Para>
                                    </ListItem>
                                 </UnorderedList>
                              </td></tr><tr><td>
                                 <Addition xmlns="http://www.legislation.gov.uk/namespaces/legislation" ChangeId="O001001M009" CommentaryRef="c000002">D</Addition>
                                 <Inferior xmlns="http://www.legislation.gov.uk/namespaces/legislation">
                                    <Addition ChangeId="O001001M009" CommentaryRef="c000002">ROOF</Addition>
                                 </Inferior>
                                 <Addition xmlns="http://www.legislation.gov.uk/namespaces/legislation" ChangeId="O001001M009" CommentaryRef="c000002"> (t4)</Addition>
                              </td><td>
                                 <Para xmlns="http://www.legislation.gov.uk/namespaces/legislation">
                                    <Text>
                                       <Addition ChangeId="O001001M009" CommentaryRef="c000002">All of the following conditions must be satisfied:</Addition>
                                    </Text>
                                 </Para>
                                 <UnorderedList xmlns="http://www.legislation.gov.uk/namespaces/legislation" Decoration="dash">
                                    <ListItem>
                                       <Para>
                                          <Text>
                                             <Addition ChangeId="O001001M009" CommentaryRef="c000002">Roof system is penetrated within 30 minutes but is not penetrated in the preliminary flame test</Addition>
                                          </Text>
                                       </Para>
                                    </ListItem>
                                    <ListItem>
                                       <Para>
                                          <Text>
                                             <Addition ChangeId="O001001M009" CommentaryRef="c000002">In the preliminary test, after withdrawal of test flame, specimens burn for &lt; 5 minutes</Addition>
                                          </Text>
                                       </Para>
                                    </ListItem>
                                    <ListItem>
                                       <Para>
                                          <Text>
                                             <Addition ChangeId="O001001M009" CommentaryRef="c000002">In the preliminary test, flame spread &lt; 0.38 m across the region of burning</Addition>
                                          </Text>
                                       </Para>
                                    </ListItem>
                                 </UnorderedList>
                              </td></tr><tr><td>
                                 <Addition xmlns="http://www.legislation.gov.uk/namespaces/legislation" ChangeId="O001001M009" CommentaryRef="c000002">E</Addition>
                                 <Inferior xmlns="http://www.legislation.gov.uk/namespaces/legislation">
                                    <Addition ChangeId="O001001M009" CommentaryRef="c000002">ROOF</Addition>
                                 </Inferior>
                                 <Addition xmlns="http://www.legislation.gov.uk/namespaces/legislation" ChangeId="O001001M009" CommentaryRef="c000002"> (t4)</Addition>
                              </td><td>
                                 <Para xmlns="http://www.legislation.gov.uk/namespaces/legislation">
                                    <Text>
                                       <Addition ChangeId="O001001M009" CommentaryRef="c000002">All of the following conditions must be satisfied:</Addition>
                                    </Text>
                                 </Para>
                                 <UnorderedList xmlns="http://www.legislation.gov.uk/namespaces/legislation" Decoration="dash">
                                    <ListItem>
                                       <Para>
                                          <Text>
                                             <Addition ChangeId="O001001M009" CommentaryRef="c000002">Roof system is penetrated within 30 minutes but is not penetrated in the preliminary flame test</Addition>
                                          </Text>
                                       </Para>
                                    </ListItem>
                                    <ListItem>
                                       <Para>
                                          <Text>
                                             <Addition ChangeId="O001001M009" CommentaryRef="c000002">Flame spread is not controlled</Addition>
                                          </Text>
                                       </Para>
                                    </ListItem>
                                 </UnorderedList>
                              </td></tr><tr><td>
                                 <Addition xmlns="http://www.legislation.gov.uk/namespaces/legislation" ChangeId="O001001M009" CommentaryRef="c000002">F</Addition>
                                 <Inferior xmlns="http://www.legislation.gov.uk/namespaces/legislation">
                                    <Addition ChangeId="O001001M009" CommentaryRef="c000002">ROOF</Addition>
                                 </Inferior>
                                 <Addition xmlns="http://www.legislation.gov.uk/namespaces/legislation" ChangeId="O001001M009" CommentaryRef="c000002"> (t4)</Addition>
                              </td><td>
                                 <Addition xmlns="http://www.legislation.gov.uk/namespaces/legislation" ChangeId="O001001M009" CommentaryRef="c000002">No performance determined</Addition>
                              </td></tr></tbody>
                     </table>
                  </Tabular>
               </Division>
            </ScheduleBody>
         </Schedule>
      </Schedules>
   </EURetained><Footnotes><Footnote id="f00001">
         <FootnoteText>
            <Para>
               <Text>
                  <Citation id="c00001" Class="EuropeanUnionOfficialJournal" Year="1989" URI="https://webarchive.nationalarchives.gov.uk/eu-exit/https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=uriserv:OJ.L_.1989.040.01.0012.01.ENG" Date="1989-02-11">OJ L 40, 11.2.1989, p. 12</Citation>.</Text>
            </Para>
         </FootnoteText>
      </Footnote><Footnote id="f00002">
         <FootnoteText>
            <Para>
               <Text>
                  <Citation id="c00002" Class="EuropeanUnionOfficialJournal" Year="1993" URI="https://webarchive.nationalarchives.gov.uk/eu-exit/https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=uriserv:OJ.L_.1993.220.01.0001.01.ENG" Date="1993-08-30">OJ L 220, 30.8.1993, p. 1</Citation>.</Text>
            </Para>
         </FootnoteText>
      </Footnote><Footnote id="f00003">
         <FootnoteText>
            <Para>
               <Text>
                  <Citation id="c00003" Class="EuropeanUnionOfficialJournal" Year="1994" URI="https://webarchive.nationalarchives.gov.uk/eu-exit/https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=uriserv:OJ.C_.1994.062.01.0001.01.ENG" Date="1994-02-28">OJ C 62, 28.2.1994, p. 1</Citation>.</Text>
            </Para>
         </FootnoteText>
      </Footnote><Footnote id="f00004">
         <FootnoteText>
            <Para>
               <Text>
                  <Citation id="c00004" Class="EuropeanUnionOfficialJournal" Year="2000" URI="https://webarchive.nationalarchives.gov.uk/eu-exit/https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=uriserv:OJ.L_.2000.235.01.0019.01.ENG" Date="2000-09-19">OJ L 235, 19.9.2000, p. 19</Citation>.</Text>
            </Para>
         </FootnoteText>
      </Footnote></Footnotes><Commentaries><Commentary Type="F" Source="EU" id="c000001">
         <Para>
            <Text>Substituted by <Citation Class="EuropeanUnionDecision" Year="2005" Number="823" URI="http://www.legislation.gov.uk/id/eudn/2005/823" Title="Commission Decision of 22 November 2005 amending Decision 2001/671/EC implementing Council Directive 89/106/EEC as regards the classification of the external fire performance of roofs and roof coverings (notified under document number C(2005) 4437) (Text with EEA relevance) (2005/823/EC)">Commission Decision of 22 November 2005 amending Decision 2001/671/EC implementing Council Directive 89/106/EEC as regards the classification of the external fire performance of roofs and roof coverings (notified under document number C(2005) 4437) (Text with EEA relevance) (2005/823/EC)</Citation>.</Text>
         </Para>
      </Commentary><Commentary Type="F" Source="EU" id="c000002">
         <Para>
            <Text>Inserted by <Citation Class="EuropeanUnionDecision" Year="2005" Number="823" URI="http://www.legislation.gov.uk/id/eudn/2005/823" Title="Commission Decision of 22 November 2005 amending Decision 2001/671/EC implementing Council Directive 89/106/EEC as regards the classification of the external fire performance of roofs and roof coverings (notified under document number C(2005) 4437) (Text with EEA relevance) (2005/823/EC)">Commission Decision of 22 November 2005 amending Decision 2001/671/EC implementing Council Directive 89/106/EEC as regards the classification of the external fire performance of roofs and roof coverings (notified under document number C(2005) 4437) (Text with EEA relevance) (2005/823/EC)</Citation>.</Text>