Table,
CLASSES OF EXTERNAL FIRE PERFORMANCE FOR ROOFS/ROOF COVERINGS  ,
    The number of classes is still under review and will be amended as soon as the necessary information is available.    ,
 *  Attention shall be drawn to dripping from the underside of the specimen, any mechanical failure and any development of holes by adding a suffix “ x ” to the designation to denote that one or more of these took place during the test. In addition, depending upon inclination of the product during the test, the letters EXT.F will be added to indicate “ flat or horizontal ” and EXT.S will be added to indicate “ inclined ” . ,

CR1187:2001 test 1,B ROOF (t1),  All of the following conditions must be satisfied:      external and internal fire spread upwards &lt; 0,700 m,      external and internal fire spread downwards &lt; 0,600 m,      maximum burned length external and internal &lt; 0,800 m,      no burning material (droplets or debris) falling from exposed side,      no burning/glowing particles penetrating the roof construction,      no single through opening &gt; 2,5 × 10 –5  m 2 ,      sum of all through openings &lt; 4,5 × 10 –3  m 2 ,      lateral fire spread does not reach the edges of the measurement zone,      no internal glowing combustion,      maximum redius of fire spread on ‘horizontal’, roofs, external and internal &lt; 0,200 m.    ,
F ROOF (t1),No performance determined,
CR1187:2001 test 2,B ROOF (t2),  For both test series at 2 m/s and 4 m/s wind speed:      mean damaged length of the roofing and underlay ≤ 0,550 m,      maximum damaged length of the roofing and underlay ≤ 0,800 m,    ,
F ROOF (t2),No performance determined,
CR1187:2001 test 3,B ROOF (t3),T E ≥ 30 min and T P ≥ 30 min,
C ROOF (t3),T E ≥ 10 min and T P ≥ 15 min,
D ROOF (t3),T P &gt; 5 min,
F ROOF (t3),No performance determined,
 ENV 1187:2002 test 4 , B   ROOF   (t4) ,   All of the following conditions must be satisfied:        No penetration of roof system within 1 hour        In the preliminary test, after withdrawal of test flame, specimens burn for &lt; 5 minutes        In the preliminary test, flame spread &lt; 0.38 m across the region of burning     ,
 C   ROOF   (t4) ,   All of the following conditions must be satisfied:        No penetration of roof system within 30 minutes        In the preliminary test, after withdrawal of test flame, specimens burn for &lt; 5 minutes        In the preliminary test, flame spread &lt; 0.38 m across the region of burning     ,
 D   ROOF   (t4) ,   All of the following conditions must be satisfied:        Roof system is penetrated within 30 minutes but is not penetrated in the preliminary flame test        In the preliminary test, after withdrawal of test flame, specimens burn for &lt; 5 minutes        In the preliminary test, flame spread &lt; 0.38 m across the region of burning     ,
 E   ROOF   (t4) ,   All of the following conditions must be satisfied:        Roof system is penetrated within 30 minutes but is not penetrated in the preliminary flame test        Flame spread is not controlled     ,
 F   ROOF   (t4) , No performance determined ,