Regulations 12(1) and (2) and 17(3)
1. The product information sheet must contain the information set out in Table 6.
Supplier’s name or trade mark: | ||||
Supplier’s address: | ||||
Model identifier: | ||||
Type of light source: | ||||
Lighting technology used: | [HL/LFL T5 HE/LFL T5 HO/CFLni/other FL/HPS/MH/other HID/LED/OLED/mixed/other] | Non-directional or directional: | [NDLS/DLS] | |
Light source cap-type (or other electric interface) | [Free text] | |||
Mains or non-mains: | [MLS/NMLS] | Connected light source (CLS): | [yes/no] | |
Colour-tuneable light source: | [yes/no] | Envelope: | [no/second/non-clear] | |
High luminance light source: | [yes/no] | |||
Anti-glare shield: | [yes/no] | Dimmable: | [yes/only with specific dimmers/no] | |
Product parameters | ||||
Parameter | Value | Parameter | Value | |
General product parameters | ||||
Energy consumption in on-mode (kWh/1,000 h) rounded up to the nearest integer | x | Energy efficiency class | [A/B/C/D/E/F/G] | |
Useful luminous flux (Φuse), indicating if it refers to the flux in a sphere (360°), in a wide cone (120°) or in a narrow cone (90°) | x in [sphere/wide cone/narrow cone] | Correlated colour temperature, rounded to the nearest 100K, or the range of correlated colour temperatures, rounded to the nearest 100K, that can be set | [x/x…x/x or x (or x…)] | |
On-mode power (Pon), expressed in W | x.x | Standby power (Psb), expressed in W and rounded to the second decimal point | x.xx | |
Networked standby power (Pnet) for CLS, expressed in W and rounded to the second decimal point | x.xx | Colour rendering index, rounded to the nearest integer, or the range of CRI-values that can be set | [x/x…x] | |
Outer dimensions without separate control gear, lighting control parts and non-lighting control parts, if any (millimetre) | Height | x | Spectral power distribution in the range 250 nm to 800 nm, at full-load | [graphic] |
Width | x | |||
Depth | x | |||
Claim of equivalent power (see paragraph [2(1) and (2)]) | [yes/-] | If yes, equivalent power (W) | x | |
Chromaticity coordinates (x and y) | 0.xxx 0.xxx | |||
Parameters for directional light sources: | ||||
Peak luminous intensity (cd) | x | Beam angle in degrees, or the range of beam angles that can be set | [x/x…x] | |
Parameters for LED and OLED light sources: | ||||
R9 colour rendering index value | x | Survival factor | x.xx | |
The lumen maintenance factor | x.xx | |||
Parameters for LED and OLED mains light sources: | ||||
Displacement factor (cos φ1) | x.xx | Colour consistency in McAdam ellipses | x | |
Claims that an LED light source replaces a fluorescent light source without integrated ballast of a particular wattage (see paragraph [2(3)]. | [yes/-] | If yes then replacement claim (W) | x | |
Flicker metric (Pst LM) | x.x | Stroboscopic effect metric (SVM) | x.x |
2.—(1) An equivalence claim involving the power of a replaced light source type may be given only—
(a)for directional light sources, if the light source type is listed in Table 7 and the luminous flux of the light source in a 90° cone (Φ90°) is not lower than the corresponding reference luminous flux in Table 7, and for this purpose—
(i)the reference luminous flux must be multiplied by the correction factor in Table 8; and
(ii)for LED light sources, it must in addition be multiplied by the correction factor in Table 9;
(b)for non-directional light sources, if the claimed equivalent incandescent light source power (in Watts, rounded to the nearest integer) corresponds to the luminous flux of the light source in Table 10.
(2) The intermediate values of both the luminous flux and the claimed equivalent light source power (in Watts, rounded to the integer) must be calculated by linear interpolation between the two adjacent values.
(3) A claim that a LED light source replaces a fluorescent light source without integrated ballast of a particular wattage may be made only if—
(a)the luminous intensity in any direction around the tube axis does not deviate by more than 25% from the average luminous intensity around the tube;
(b)the luminous flux of the LED light source is not lower than the luminous flux of the fluorescent light source of the claimed wattage; and
(c)the wattage of the LED light source is not higher than the wattage of the fluorescent light source it is claimed to replace.
(4) For light sources that can be tuned to emit light at full-load with different characteristics, the values of parameters that vary with these characteristics must be reported at the reference control settings.
(5) For the purposes of sub-paragraph (3)(b), the luminous flux of the fluorescent light source must be obtained by multiplying the claimed wattage with the minimum luminous efficacy value corresponding to the fluorescent light source in Table 11.
Type | Power | Reference Φ90° (lm) |
Extra-low voltage reflector type | ||
MR11 GU4 | 20 | 160 |
35 | 300 | |
MR16 GU 5.3 | 20 | 180 |
35 | 300 | |
50 | 540 | |
AR111 | 35 | 250 |
50 | 390 | |
75 | 640 | |
100 | 785 | |
Mains-voltage blown glass reflector type | ||
R50/NR50 | 25 | 90 |
40 | 170 | |
R63/NR63 | 40 | 180 |
60 | 300 | |
R80/NR80 | 60 | 300 |
75 | 350 | |
100 | 580 | |
R95/NR95 | 75 | 350 |
100 | 540 | |
R125 | 100 | 580 |
150 | 1,000 | |
Mains-voltage pressed glass reflector type | ||
PAR16 | 20 | 90 |
25 | 125 | |
35 | 200 | |
50 | 300 | |
PAR20 | 35 | 200 |
50 | 300 | |
75 | 500 | |
PAR25 | 50 | 350 |
75 | 550 | |
PAR30S | 50 | 350 |
75 | 550 | |
100 | 750 | |
PAR36 | 50 | 350 |
75 | 550 | |
100 | 720 | |
PAR38 | 60 | 400 |
75 | 555 | |
80 | 600 | |
100 | 760 | |
120 | 900 |
Light source type | Luminous flux multiplication factor |
---|---|
Halogen light sources | 1 |
Fluorescent light sources | 1.08 |
LED light sources | 1 + 0.5 × (1 - LLMF) where LLMF is the lumen maintenance factor at the end of the declared lifetime |
LED light source beam angle | Luminous flux multiplication factor |
---|---|
20° ≤ beam angle | 1 |
15° ≤ beam angle < 20° | 0.9 |
10° ≤ beam angle < 15° | 0.85 |
beam angle < 10° | 0.8 |
Light source luminous flux Φ (lm) | Claimed equivalent incandescent light source power (W) |
---|---|
136 | 15 |
249 | 25 |
470 | 40 |
806 | 60 |
1,055 | 75 |
1,521 | 100 |
2,452 | 150 |
3,452 | 200 |
T8 (26 mm Ø) | T5 (16 mm Ø) High Efficiency | T5 (16 mm Ø) High output | |||
---|---|---|---|---|---|
Claimed equivalent power (W) | Minimum luminous efficacy (lm/W) | Claimed equivalent power (W) | Minimum luminous efficacy (lm/W) | Claimed equivalent power (W) | Minimum luminous efficacy (lm/W) |
15 | 63 | 14 | 86 | 24 | 73 |
18 | 75 | 21 | 90 | 39 | 79 |
25 | 76 | 28 | 93 | 49 | 88 |
30 | 80 | 35 | 94 | 54 | 82 |
36 | 93 | 80 | 77 | ||
38 | 87 | ||||
58 | 90 | ||||
70 | 89 |
3.—(1) If a light source is placed on the market as a part in a containing product, the following statement must be displayed, clearly legible, in the user manual or booklet of instructions—
“This product contains a light source of energy efficiency class <X>”,
where <X> is to be replaced by the energy efficiency class of the contained light source.
(2) If the product contains more than one light source, the statement referred to in sub-paragraph (1) may be in the plural, or repeated for each light source, as appropriate.
4. The following information must be shown, accessible to the public without charge, on the supplier’s website—
(a)the reference control settings, and instructions on how they can be implemented, where applicable;
(b)instructions on how to remove lighting control parts or non-lighting parts, if any, or how to switch them off or minimise their power consumption;
(c)if the light source is dimmable—
(i)a list of dimmers with which it is compatible; and
(ii)the light source-dimmer compatibility standard with which it is compliant, if any;
(d)if the light source contains mercury, instructions on how to clean up the debris in case of accidental breakage;
(e)recommendations on how to dispose of the light source at the end of its life in line with the Waste Electrical and Electronic Equipment Regulations 2013.
Y Diweddaraf sydd Ar Gael (diwygiedig):Y fersiwn ddiweddaraf sydd ar gael o’r ddeddfwriaeth yn cynnwys newidiadau a wnaed gan ddeddfwriaeth ddilynol ac wedi eu gweithredu gan ein tîm golygyddol. Gellir gweld y newidiadau nad ydym wedi eu gweithredu i’r testun eto yn yr ardal ‘Newidiadau i Ddeddfwriaeth’.
Gwreiddiol (Fel y’i Deddfwyd neu y’i Gwnaed): Mae'r wreiddiol fersiwn y ddeddfwriaeth fel ag yr oedd pan gafodd ei deddfu neu eu gwneud. Ni wnaed unrhyw newidiadau i’r testun.
Mae Memoranda Esboniadol yn nodi datganiad byr o ddiben Offeryn Statudol ac yn rhoi gwybodaeth am ei amcan polisi a goblygiadau polisi. Maent yn ceisio gwneud yr Offeryn Statudol yn hygyrch i ddarllenwyr nad oes ganddynt gymhwyster cyfreithiol, ac maent yn cyd-fynd ag unrhyw Offeryn Statudol neu Offeryn Statudol Drafft a gyflwynwyd ger bron y Senedd o Fehefin 2004 ymlaen.
Gallwch wneud defnydd o ddogfennau atodol hanfodol a gwybodaeth ar gyfer yr eitem ddeddfwriaeth o’r tab hwn. Yn ddibynnol ar yr eitem ddeddfwriaeth sydd i’w gweld, gallai hyn gynnwys:
Impact Assessments generally accompany all UK Government interventions of a regulatory nature that affect the private sector, civil society organisations and public services. They apply regardless of whether the regulation originates from a domestic or international source and can accompany primary (Acts etc) and secondary legislation (SIs). An Impact Assessment allows those with an interest in the policy area to understand:
Defnyddiwch y ddewislen hon i agor dogfennau hanfodol sy’n cyd-fynd â’r ddeddfwriaeth a gwybodaeth am yr eitem hon o ddeddfwriaeth. Gan ddibynnu ar yr eitem o ddeddfwriaeth sy’n cael ei gweld gall hyn gynnwys:
liciwch ‘Gweld Mwy’ neu ddewis ‘Rhagor o Adnoddau’ am wybodaeth ychwanegol gan gynnwys