Regulation 8(5) and (8)
The following data-quality objectives for the required accuracy of assessment methods, of minimum time coverage and of data capture of measurement are laid down to guide quality-assurance programmes.
| Sulphur dioxide, nitrogen dioxide and oxides of nitrogen | Particulate matter and lead | |
|---|---|---|
The accuracy of the measurement is defined as laid down in the “Guide to the Expression of Uncertainty of Measurements ” (ISO 1993)(1) or in ISO 5725-1 “Accuracy (trueness and precision) of measurement methods and results ” (ISO 1994)(2). The percentages in the table are given for individual measurements averaged, over the period considered, by the limit value, for a 95% confidence interval (bias + two times the standard deviation). The accuracy for continuous measurements should be interpreted as being applicable in the region of the appropriate limit value. The accuracy for modelling and objective estimation is defined as the maximum deviation of the measured and calculated concentration levels, over the period considered by the limit value, without taking account the timing of the events. The requirements for minimum data capture and time coverage do not include losses of data due to the regular calibration or the normal maintenance of the instrumentation. The National Assembly may allow for random measurements to be made instead of continuous measurements for particulate matter and lead by methods for which accuracy within the 95% confidence interval with respect to continuous monitoring has been demonstrated to be within 10%. Random sampling must be spread evenly over the year. | ||
| Continuous measurement | ||
| Accuracy | 15% | 25% |
| Minimum data capture | 90% | 90% |
| Indicative measurement | ||
| Accuracy | 25% | 50% |
| Minimum data capture | 90% | 90% |
| Minimum time coverage | 14% (One measurement a week at random, evenly distributed over the year, or eight weeks evenly distributed over the year.) | 14% (One measurement a week at random, evenly distributed over the year, or eight weeks evenly distributed over the year.) |
| Modelling | ||
| Accuracy: | ||
| Hourly averages | 50%—60% | |
| Daily averages | 50% | |
| Annual averages | 30% | 50% |
| Objective estimation | ||
| Accuracy: | 75% | 100% |
The following data quality objectives, for allowed uncertainty of assessment methods, and of minimum time coverage and of data capture of measurement are provided to guide quality assurance programmes.
| Benzene | Carbon monoxide | |
|---|---|---|
The uncertainty (on a 95% confidence interval) of the assessment methods shall be evaluated in accordance with the “Guide to the Expression of Uncertainty of Measurements” (ISO 1993)(3) or the methodology of ISO 5725:1994(4). The percentages for uncertainty in the above table are given for individual measurements averaged over the period considered by the limit value, for a 95% confidence interval. The uncertainty for the fixed measurements should be interpreted as being applicable in the region of the appropriate limit value. The uncertainty for modelling and objective estimation is defined as the maximum deviation of the measured and calculated concentration levels, over the period considered, by the limit value, without taking into account the timing of the events. The requirements for minimum data capture and time coverage do not include losses of data due to the regular calibration of the normal maintenance of the instrumentation. The National Assembly may allow for random measurements to be made instead of continuous measurements for benzene if the uncertainty, including the uncertainty due to random sampling, meets the quality objective of 25%. Random sampling must be spread evenly across the year. | ||
| Fixed measurements | ||
| Uncertainty | 25% | 15% |
| Minimum data capture | 90% | 90% |
| Minimum time coverage | 35% urban background and traffic sites (distributed over the year to be representative of various conditions for climate and traffic) 90% industrial sites | |
| Indicative measurements | ||
| Uncertainty | 30% | 25% |
| Minimum data capture | 90% | 90% |
| Minimum time coverage | 14% (one day’s measurement a week at random, evenly distributed over the year, or 8 weeks evenly distributed over the year) | 14% (one measurement a week at random, evenly distributed over the year, or 8 weeks evenly distributed over the year) |
| Modelling | ||
| Uncertainty: | ||
| Eight-hour averages | — | 50% |
| Annual averages | 50% | — |
| Objective estimation | ||
| Uncertainty | 100% | 75% |
The following information should be compiled for zones and agglomerations within which sources other than measurement are employed to supplement information from measurement or as the sole means of air quality assessment:
a description of assessment activities carried out;
the specific methods used, with references to descriptions of the method;
the sources of data and information;
a description of results, including accuracies and, in particular, the extent of any area or, if relevant, the length of road within the zone over which concentrations exceed limit value(s) or, as may be, limit value(s) plus applicable margin(s) of tolerance and of any area within which concentrations exceed the upper assessment threshold or the lower assessment threshold;
for limit values the object of which is the protection of human health, the population potentially exposed to concentrations in excess of the limit value.
Where possible maps shall be compiled showing concentration distributions within each zone and agglomeration.
Copies of this International Standards Organisation publication can be purchased from the British Standards Institution “BSI” sales department either by telephone on 020-8996-9001 or by post from the BSI, Standards House, 389 Chiswick High Road, London W4 4AL.
Copies of this International Standards Organisation publication can be purchased from the British Standards Institution “BSI” as for footnote (a) above.
Copies of this International Standards Organisation publication can be purchased from the British Standards Institution “BSI” sales department either by telephone on 020-8996-9001 or by post from the BSI, Standards House, 389 Chiswick High Road, London W4 4AL.
Copies of this International Standards Organisation publication can be purchased from the British Standards Institution “BSI” as for footnote (a) above.
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area. The revised version is currently only available in English.
Original (As Enacted or Made) - English:The original English language version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.
Original (As Enacted or Made) - Welsh:The original Welsh language version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: