5. Equipment for measuring PM2.5 levels at monitoring stations must be positioned in accordance with the following criteria—
(a)the flow of air around the sampling inlet must be unrestricted (free in an arc of at least 180° if the equipment is affixed or adjacent to a building or 270° otherwise);
(b)the sampling inlet must—
(i)be not less than 0.5 metres from the nearest building, tree or other obstacle; and
(ii)not be positioned in the immediate vicinity of a source of PM2.5 emissions;
(c)the height of the inlet sampling probe must be not less than 1.5 metres and not more than 8 metres above the ground;
(d)the sampler’s exhaust outlet must be positioned so that recirculation of exhaust air to the sampler inlet is avoided.
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.
Explanatory Memorandum sets out a brief statement of the purpose of a Statutory Instrument and provides information about its policy objective and policy implications. They aim to make the Statutory Instrument accessible to readers who are not legally qualified and accompany any Statutory Instrument or Draft Statutory Instrument laid before Parliament from June 2004 onwards.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
Impact Assessments generally accompany all UK Government interventions of a regulatory nature that affect the private sector, civil society organisations and public services. They apply regardless of whether the regulation originates from a domestic or international source and can accompany primary (Acts etc) and secondary legislation (SIs). An Impact Assessment allows those with an interest in the policy area to understand:
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: