- Latest available (Revised)
- Original (As made)
This is the original version (as it was originally made).
5.—(1) Each monopile foundation forming part of the authorised development shall not have a diameter greater than 6.5 metres.
(2) Each gravity base foundation forming part of the authorised development shall not have—
(a)a diameter at the level of the seabed which is greater than 34 metres;
(b)a base height, where there is a flat base, which is greater than 10 metres above the level of the seabed.
(3) Each jacket foundation forming part of the authorised development shall not have—
(a)a width spacing between each leg at the level of the seabed which is greater than 32 metres;
(b)a leg diameter which is greater than 2.6 metres;
(c)a pile diameter which is more than 2.6 metres;
(d)more than one pile per leg;
(e)more than four legs.
(4) Each tripod foundation forming part of the authorised development shall not have—
(a)a pile diameter which is greater than 2.8 metres;
(b)more than one pile per leg;
(c)more than three legs;
(d)a column diameter which is greater than 4.5 metres.
(5) Each suction caisson foundation forming part of the authorised development shall not have—
(a)a diameter at the level of the seabed which is more than 35 metres;
(b)a column diameter which is more than 6.5 metres.
(6) Each IBGS foundation forming part of the authorised development shall not have—
(a)a width spacing between each leg at the level of the seabed which is greater than 26 metres;
(b)a central pile diameter which is greater than 2.8 metres; and
(c)a raking pile diameter which is greater than 1.5 metres.
(7) No more than 156 monopile foundations shall be installed as part of the authorised development.
(8) No more than 124 jacket foundations shall be installed as part of the authorised development.
(9) No more than 124 IBGS foundations shall be installed as part of the authorised development.
(10) No more than 165 tripod foundations shall be installed as part of the authorised development.
(11) No more than 80 gravity base foundations shall be installed as part of the authorised development.
(12) No more than 118 suction caisson foundations shall be installed as part of the authorised development.
(13) The total amount of scour protection for the WTGs and offshore substations forming part of the authorised development shall not exceed 831,400m3.
The Whole Instrument you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.
Would you like to continue?
The Whole Instrument you have selected contains over 200 provisions and might take some time to download.
Would you like to continue?
The Whole Instrument you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.
Would you like to continue?
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: