Regulation 4(1)(a)

SCHEDULE 1CALCULATION OF MAXIMUM ALLOWABLE ELECTRICITY CONSUMPTION

1.  The energy efficiency of the ballast-lamp circuit is determined by the maximum input power into the circuit. This is a function of the lamp power and of the type of ballast. The maximum input power of ballast-lamp circuits of a given ballast is defined as the maximum ballast-lamp circuit power, with different levels for each lamp power and ballast type.

2.  Expressions used in this Schedule have the same meaning as in European Standard EN50294.

3.  The ballast shall first be allocated to the appropriate category from the following list:

CategoryDescription
1Ballast for linear lamp type
2Ballast for compact 2 tubes lamp type
3Ballast for compact 4 tubes flat lamp type
4Ballast for compact 4 tubes lamp type
5Ballast for compact 6 tubes lamp type
6Ballast for compact 2 D lamp type

4.  The maximum allowable input power of a ballast-lamp circuit—

(a)in the period before 21st November 2005, shall be that shown in column 3(a) of the Table below;

(b)in the period beginning with that date, shall be that shown in column 3(b) of that Table.

TABLE

Maximum input power of ballast-lamp circuits

Ballast categoryLamp PowerMaximum input power of Ballast-lamp circuits
Column 1Column 2Column 3
50HzHF(a)(b)
115 W13.5 W25 W23 W
18 W16 W28 W26 W
30 W24 W 40 W38 W
36 W32 W45 W43 W
38 W32 W47 W45 W
58 W50 W70 W67 W
70 W60 W83 W80 W
218 W16 W28 W26 W
24 W22 W34 W32 W
36 W32 W45 W43 W
318 W16 W28 W26 W
24 W22 W34 W32 W
36 W32 W45 W43 W
410 W9.5 W18 W16 W
13 W12.5 W21 W19 W
18 W16.5 W28 W26 W
26 W24 W36 W34 W
518 W16 W28 W26 W
26 W24 W36 W34 W
610 W9 W18 W16 W
16 W14 W25 W23 W
21 W19 W31 W29 W
28 W25 W38 W36 W
38 W34 W47 W45 W

5.  Whenever a ballast is designed for a lamp which falls between two values indicated in the above Table, the maximum input power of the ballast-lamp circuit shall be calculated by linear interpolation between the two values of maximum power for the two closest lamps indicated in the Table.

For example if a ballast in lamp category 1 is rated for a 48W lamp at 50Hz, the maximum input power of the ballast-lamp circuit shall be calaculated as follows—

(a)in the period before 21st November 2005—

(b)in the period beginning with that date—

Back to top

Options/Help

Print Options

Close

Legislation is available in different versions:

Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.

Original (As Enacted or Made):The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.

Close

Opening Options

Different options to open legislation in order to view more content on screen at once

Close

More Resources

Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as enacted version that was used for the print copy
  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • correction slips
  • links to related legislation and further information resources
Close

More Resources

Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as made version that was used for the print copy
  • correction slips

Click 'View More' or select 'More Resources' tab for additional information including:

  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • links to related legislation and further information resources