09-19Synthetic aromatic hydrocarbon insulating fluid for use in fluid-filled pressure-assisted cables up to 400kV operating voltage Issue 2, 1996
09-22Protection of cable installations against the effects of fire Issue 1, 1997
12-4Terminating equipment for pilot cables subject to induced transient voltages exceeding 650V rms Amendment 1, 1996 to Issue 1, 1973
12-25Cable trays Issue 1, 1997
35-17Class X current transformers Issue 1, 1996
41-26Distribution switchgear for service up to 36kV (cable connected) Amendment 3, 1997 to Issue 1, 1991
41-27Outdoor distribution switchgear for service up to 36kV (overhead conductor connected) Amendment 3, 1997 to Issue 1, 1991
43-2Design of steel tower overhead transmission lines at 132kV and higher voltages Amendment 1, 1996 to Issue 1, 1972
43-3Design of lattice steel transmission towers for overhead lines at 132kV and higher voltages Amendment 1, 1996 to Issue 1, 1972
43-6Construction of overhead transmission lines on steel towers for 132kV and higher voltages Amendment 1, 1996 to Issue 2, 1986
43-8Overhead line clearances Amendment 2, 1996 to Issue 2, 1988
43-11400kV steel tower transmission lines—specification L.12 (2 x 700 mm2 AAAC per phase) (1 x 425 mm2 AAAC earthwire) Amendment 1, 1996 to Issue 1, 1984
43-96Fasteners and washers for wood pole overhead lines Corrigendum, 1996 to Amendment 1, 1995 to Issue 2, 1986
43-97Steel supports for single circuit 132kV overhead lines Amendment 1, 1996 to Issue 1, 1990
43-99Limits and measurement of radio noise from cap and pin insulators Issue 1, 1997
43-100Conductor tensions and sags Issue 1, 1997
43-101Line and earth conductors Issue 1, 1997
43-102Insulators and fittings for 132kV lines Issue 1, 1997
43-104Spacers for twin and quad line conductors Issue 1, 1997
43-105Bi-metal connectors for line conductors Issue 1, 1997
43-106Tubular jumpers and earthing bars for twin line conductors Issue 1, 1997
43-107Selection of earthwire changeover towers for 400kV lines with 4 x 61/.125 in s.c.a. conductors per phase Issue 1, 1997
43-108Suspension clamps for conductors Issue 1, 1997
43-109Bonds for earth conductors Issue 1, 1997
43-110Tension joints (mid span joints) for conductors Issue 1, 1997
43-111Non-tension joints and tee connectors for conductors Issue 1, 1997
43-112Repair sleeves for conductors Issue 1, 1997
43-113Vibration dampers for conductors Issue 1, 1997
43-114Anchor clamps for conductors Issue 1, 1997
43-115Insulators and fittings for 275kV lines Issue 1, 1997
43-116Insulators and fittings for 400kV lines Issue 1, 1997
43-117Installation of aluminium current carrying overhead line conductor fittings Issue 1, 1997
43-118Overhead line erection and maintenance equipment (earthed working) Issue 1, 1997
43-119Design and use of temporary scaffold guards Issue 1, 1997
48-5Environmental test requirements for protection relays and systems Issue 1, 1996
50-9Equipment for work on cables under induced voltage conditions Issue 1, 1997
97-1Special backfill materials for cable installations Issue 1, 1997
98-1Surface preparation and coating systems for new plant and equipment Issue 2, 1997
C97Code of Practice on the marking of high-voltage cable routes 1997
G56/1Arrangements for access by EA Member Company staff to Railtrack Infrastucture 1996
G75Recommendations for the connection of embedded generating plant to Public Electricity Suppliers' distribution systems above 20kV or with outputs over 5MW 1996
G76Guide to the Audit and Certification of Suppliers' Quality Management Systems
Part 1: Guide to the Organisation and Operation of Accredited Third Party Certification Bodies 1996
Part 2 (a): Guide to the audit of the Quality Management Systems of Suppliers of High Voltage Switchgear 1996
Part 2 (b): Guide to the Audit of the Quality Management Systems of Suppliers of Low Voltage and High Voltage Cable and Accessories 1996
Part 2 (c): Guide to the Audit of the Quality Management Systems of Suppliers of High Voltage Transformers and Reactors 1997
L43Design and use of skycradles at line crossings of motorways, other major roads and railways 1997
P25/1The short-circuit characterisitcs of Public Electricity Suppliers' low voltage distribution networks and the co-ordination of overcurrent protective devices on 230V single phase supplies up to 100A 1996
TELE.2Installation of optical cabling in hazardous areas: Overhead power lines 1997
EB/BT.2Conditions for BT and Public Electricity Suppliers' joint use of poles 1996

Back to top

Options/Help

Print Options

Close

Legislation is available in different versions:

Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.

Original (As Enacted or Made):The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.

Close

Opening Options

Different options to open legislation in order to view more content on screen at once