PART II—FIRE PREVENTION AND FIRE APPLIANCES

Passenger Ships

SHIPS OF CLASS III OF 21.34 METRES IN LENGTH OR OVER

Machinery spaces of Category A

8.—(1) In every ship of Class III of 21.34 metres in length or over there shall be provided for the protection of any machinery space of Category A at least one of the following fixed fire-extinguishing systems—

(a)a fixed pressure water-spraying system complying with the requirements of Schedule 2 of Merchant Shipping Notice MSN 1666;

(b)a fixed gas fire-extinguishing system complying with the requirements of Schedule 4 of Merchant Shipping Notice MSN 1666;

(c)a high expansion foam system complying with the requirements of Schedule 8 of Merchant Shipping Notice MSN;

(d)for ships built before 25th May 1980, a foam fire-extinguishing system complying with the requirements of regulation 33.

(2) In addition to the requirements of paragraph (1) there shall be provided—

(a)in each boiler room two or more foam fire extinguishers each of at least 45 litres capacity or carbon dioxide fire extinguishers each of at least 16 kilogrammes capacity; the extinguishers shall be sited so as to be readily accessible in the event of fire and they shall be sufficient in number to enable foam or carbon dioxide to be directed on to any part of the boiler room or spaces containing any part of the oil fuel installation;

(b)in each firing space and in each space which contains any part of any oil fuel installations at least two portable fire extinguishers for extinguishing oil fires;

(c)in each firing space a receptacle containing at least 0.3 cubic metre of sand or other dry material suitable for extinguishing oil fires together with a scoop for its distribution or, alternatively, an additional portable fire extinguisher suitable for extinguishing oil fires.

(3) In addition to the requirements of paragraph (1) there shall be provided in any such space containing internal combustion type machinery—

(a)one foam fire extinguisher of at least 45 litres capacity or a carbon dioxide fire extinguisher of at least 16 kilogrammes capacity; and

(b)portable fire extinguishers suitable for extinguishing oil fires, so located that an extinguisher is not more than 10 metres walking distance from any point in the space, but in no event less than two such extinguishers.