Machinery spaces of Category A

8.—(1) In every ship of Class III of 21.34 metres in length or over there shall be provided for the protection of any machinery space of Category A at least one of the following fixed fire-extinguishing systems—

(a)a fixed pressure water-spraying system complying with the requirements of Schedule 2 of Merchant Shipping Notice MSN 1666;

(b)a fixed gas fire-extinguishing system complying with the requirements of Schedule 4 of Merchant Shipping Notice MSN 1666;

(c)a high expansion foam system complying with the requirements of Schedule 8 of Merchant Shipping Notice MSN;

(d)for ships built before 25th May 1980, a foam fire-extinguishing system complying with the requirements of regulation 33.

  • If the engine room and boiler rooms are not entirely separated from each other by a bulkhead or if fuel can drain from the boiler room into the engine room, the combined engine room and boiler room shall, for the purpose of this paragraph, be regarded as a single space.

(2) In addition to the requirements of paragraph (1) there shall be provided—

(a)in each boiler room two or more foam fire extinguishers each of at least 45 litres capacity or carbon dioxide fire extinguishers each of at least 16 kilogrammes capacity; the extinguishers shall be sited so as to be readily accessible in the event of fire and they shall be sufficient in number to enable foam or carbon dioxide to be directed on to any part of the boiler room or spaces containing any part of the oil fuel installation;

(b)in each firing space and in each space which contains any part of any oil fuel installations at least two portable fire extinguishers for extinguishing oil fires;

(c)in each firing space a receptacle containing at least 0.3 cubic metre of sand or other dry material suitable for extinguishing oil fires together with a scoop for its distribution or, alternatively, an additional portable fire extinguisher suitable for extinguishing oil fires.

(3) In addition to the requirements of paragraph (1) there shall be provided in any such space containing internal combustion type machinery—

(a)one foam fire extinguisher of at least 45 litres capacity or a carbon dioxide fire extinguisher of at least 16 kilogrammes capacity; and

(b)portable fire extinguishers suitable for extinguishing oil fires, so located that an extinguisher is not more than 10 metres walking distance from any point in the space, but in no event less than two such extinguishers.

Back to top

Options/Help

Print Options

Close

Legislation is available in different versions:

Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.

Original (As Enacted or Made):The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.

Close

Opening Options

Different options to open legislation in order to view more content on screen at once

Close

More Resources

Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as enacted version that was used for the print copy
  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • correction slips
  • links to related legislation and further information resources