The Merchant Shipping (Fire Protection: Small Ships) Regulations 1998

Fire pumps

30.—(1) In every passenger ship which is required by these Regulations to be provided with fire pumps operated by power, such fire pumps (other than any emergency fire pump) shall together be capable of delivering for fire fighting purposes a quantity of water, under the conditions and at the pressure specified in regulation 31 of not less than two thirds of the quantity required to be dealt with by the bilge pumps provided in the ship in compliance with Part III of the Merchant Shipping (Passenger Ship Construction and Survey) Regulations 1984(1);

(2) In every ship, other than a passenger ship, which is required by these Regulations to be provided with fire pumps operated by power, such fire pumps (other than any emergency fire pump) shall together be capable of delivering for fire fighting purposes a quantity of water, under the conditions and at the pressure specified in Schedule 7 in Merchant Shipping Notice MSN 1665.

(3) In every ship which is required by these Regulations to be provided with more than one fire pump operated by power (other than any emergency pump) every such fire pump shall have a capacity of not less than 80 per cent of the total capacity of the fire pumps required by paragraph (1) divided by the number of fire pumps required by these Regulations to be provided in the ship, provided that each pump has a capacity of not less than 25 cubic metres per hour. When more fire pumps operated by power than are required by these Regulations are provided in any ship, the Secretary of State may permit the capacity of any such additional fire pumps to be less than 80 per cent.

(4) In every ship of Class II(A) any emergency fire pump shall be situated in a position aft of the ship’s collision bulkhead.

(1)

S.I. 1984/1216; relevant amendment is S.I. 1992/2358.