xmlns:atom="http://www.w3.org/2005/Atom"

SCHEDULE 1LIFEBOATS

PART IVMANUAL PUMPS

1.5  the pump branches shall be suitable for use with rubber hose connections of at least 30 mm bore. The metal part of the operating handle shall be suitably sheathed by material other than wood to ensure that the hands of the operator are protected when the pump is used in extreme cold. The spindle gland shall be of the spring loaded seal ring type.