4. Quarter-strength Ringer’s solution shall be used. The composition of full-strength Ringer’s solution shall be —
Sodium chloride | 9.00 grams |
Potassium chloride | 0.42 grams |
Anhydrous calcium chloride | 0.24 grams |
Sodium bicarbonate | 0.20 grams |
Distilled water | 1,000 ml. |
Add 1 part of the above solution to 3 parts of distilled water. Fill into test tubes or bottles and sterilise by autoclaving at 121°deg. for 15 minutes. The quantity to be filled into the container before sterilisation must be predetermined to allow for evaporation losses during sterilisation.
Alternatively, sterile tubes and bottles may be filled aseptically with measured quantities of sterile quarter-strength Ringer’s solution.
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: