The Reservoirs (Scotland) Regulations 2016

This section has no associated Policy Notes

10.  The following information about the reservoir as it will be when constructed, altered abandoned or discontinued—

(a)reservoir type (e.g. whether impounding, non-impounding or service reservoir);

(b)date(s) or approximate date(s) of completion of the dam(s), reservoir wall(s) or embankment(s);

(c)method of construction of the dam(s), reservoir wall(s) or embankment(s) (e.g. whether constructed of earth, rockfill, gravity, buttress or other means);

(d)maximum height of the dam(s), reservoir wall(s) or embankment(s) (in metres), measured from the lowest natural level of the surrounding land adjacent to it, to the top of the dam(s), reservoir wall(s) or embankment(s), excluding the height of the wave wall;

(e)the height of the dam(s), reservoir wall(s) or embankment(s) (in metres) measured from the lowest natural level of the surrounding land adjacent to it to the top water level;

(f)capacity (in cubic metres), measured from the lowest natural level of the surrounding land adjacent to it to the top water level; and

(g)the water surface area at the top water level (in square metres).