The Water Quality (Scotland) Regulations 2010

Amendment of the Water Supply (Water Quality) (Scotland) Regulations 2001

This section has no associated Executive Note

14.—(1) Schedule 3 to the 2001 Regulations is amended in accordance with paragraphs (2) to (4).

(2) For Table 2 substitute—

TABLE 2

ANNUAL SAMPLING FREQUENCIES: WATER SUPPLY ZONES

(1)

Substances and parameters

(2)

Estimated population

of water supply zone

(3)

Reduced

(4)

Standard

(+)

See regulation 6(2) and Table 1 in Schedule 3

(*)

Sampling for these parameters may be within water supply zones or at supply points as specified in Table 3, subject to note (ii) and (iii) below.

(i)

Where the population is not an exact multiple of 5,000, the population figure should be rounded up to the nearest multiple of 5,000.

(ii)

Audit monitoring in water supply zones is required only where sodium hypochlorite is added after water has left the treatment works. In other circumstances, audit monitoring is required at supply points.

(iii)

To monitor for total indicative dose (for radioactivity).

Subject to check monitoring
E. coli< 100                          ≥ 100–                                –4
Coliform bacteria12 per 5,000
Residual disinfectantpopulation(i)
Aluminium(+)
Ammonium
Clostridium
Perfringens (including
spores)(*) (+)
Colony counts< 10012
Colour100-4,99924
Conductivity(*)5,000-9,999612
Hydrogen ion10,000-29,9991224
Iron(+)30,000-49,9991836
Manganese(+)50,000-79,9992652
Nitrate(+)80,000-100,0003876
Nitrite(+)
Odour
Taste
Turbidity
Subject to audit monitoring
Antimony< 1001
Arsenic100-4,9994
Benzene(*)5,000-100,0008
Benzo(a)pyrene
Boron(*)
Bromate(ii) (*)
Cadmium
Chromium
Copper
Cyanide(*)
1,2 dichloroethane(*)
Enterococci
Fluoride(*)
Lead
Mercury(*)
Nickel
Pesticides(*)
PAH
Selenium
Sodium
Trichloroethene/
Tetrachloroethene(*)
Tetrachloromethane(*)
THM
Chloride(*)
Sulphate(*)
Total Organic Carbon(*)
Tritium(*)
Gross alpha(iii) (*)
Gross beta(iii) (*)
Notes:

(3) For Table 3 substitute—

TABLE 3

ANNUAL SAMPLING FREQUENCIES: SUPPLY POINTS

(1)

Item

(2)

Substances and parameters

(3)

Volume of water supplied m3/d

(4)

Reduced

(5)

Standard

(i)

Check monitoring is required only in respect of surface waters (see regulation 6(2) and Table 1 in Schedule 3), otherwise audit monitoring.

(ii)

Audit monitoring at supply points is permitted only where sodium hypochlorite is not added after water has left the treatment works. In other circumstances, audit monitoring is required in water supply zones.

(iii)

To monitor for total indicative dose (for radioactivity).

Subject to check monitoring
1.Clostridium Perfringens (including spores)(i)< 202
20–99924
2.Conductivity1,000-1,999612
2,000-5,9991224
6,000-9,9991836
10,000-15,9992652
16,000-32,99952104
33,000-49,99978156
50,000-67,999104208
68,000-84,999130260
85,000-101,999156312
102,000-119,999183365
120,000-241,999365730
242,000-484,9997301,460
485,000-728,9991,0952,190
Subject to audit monitoring
3.Benzene
4.Boron
5.Bromate(ii)
6.Cyanide
7.1,2 dichloroethane< 201
8.Fluoride20-9994
9.Mercury1,000-49,9998
10.Pesticides50,00-89,99912
11.Trichloroethene/Tetrachloroethene90,000-299,99924
12.Tetrachloromethane300,000-649,99936
13.Chloride≥ 650,00048
14.Sulphate
15.Total organic carbon
16.Tritium
17.Gross alpha(iii)
18.Gross beta(iii)
Notes:

(4) For Table 4 substitute—

TABLE 4

ANNUAL SAMPLING FREQUENCIES: WATER TREATMENT WORKS

(1)

Item

(2)

Substances and parameters

(3)

Volume of water supplied m3/d

(4)

Reduced

(5)

Standard

(i)

Check monitoring at treatment works is required only when chloramination is practised. In other circumstances, audit monitoring is required.

Subject to check monitoring
1.E. coli< 204
2.Coliform bacteria20–1,9991252
3.Colony counts2,000–5,99952104
4.Residual disinfectant6,000–11,999104208
≥12,000104365
5.Nitrite(i)< 202
6.Turbidity20-99924
1,000-1,999612
2,000-5,9991224
6,000-9,9991836
10,000-15,9992652
16,000-32,99952104
33,000-49,99978156
50,000-67,999104208
68,000-84,999130260
85,000-101,999156312
102,000-119,999183365
120,000-241,999365730
242,000-484,9997301,460
485,000-728,9991,0952,190
Subject to audit monitoring
7.Nitrite(i)< 201
20–9994
1,000–49,9998
50,000–89,99912
90,000–299,99924
300,000–649,99936
≥650,00048
Notes: