xmlns:atom="http://www.w3.org/2005/Atom"

Regulation 7

SCHEDULE 4MEASUREMENTS

Area

1.  Measurement of area shall be taken to the innermost surfaces of enclosing walls or, on any side where there is no enclosing wall, to the outermost edge of the floor on that side.

Height and depth

2.  The height of–

(a)a building shall be taken to be the height from the surface of the ground to the underside of the ceiling of the topmost storey or, if the topmost storey has no ceiling, one-half of the height of the roof above its lowest part;

(b)a storey above the ground, or the depth of a storey below the ground shall be taken to be the vertical height or depth as the case may be from the ground to the upper surface of the floor of the storey, and the expressions “a storey at a height” and “a storey at a depth” shall be construed accordingly.

3.  In the measurement of height or depth from ground which is not level the height or depth shall be taken to be the mean height or depth, except that–

(a)for the purpose of types 3, 4, 5, 18 or 19 of Schedule 3; and

(b)for any other purpose where the difference in level is more than 2.5 metres,

the height or depth shall be taken to be the greatest height or depth.

General

4.  Except where the context otherwise requires, measurements shall be horizontal and vertical.