PART 2 Group B pollutants, polycyclic aromatic hydrocarbons and total gaseous mercury

11.  The data quality objectives set out in the following table are provided to guide quality assurance—

(1)

Indicative measurement being measurements which are performed at reduced regularity but fulfil the other data quality objectives.

Benzo(a)pyrene Arsenic, cadmium and nickel Polycyclic aromatic hydrocarbons and total gaseous mercury Total deposition
Uncertainty
Fixed and indicative measurements 50% 40% 50% 70%
Modelling 60% 60% 60% 60%
Minimum data capture 90% 90% 90% 90%
Minimum time coverage
Fixed measurements 33% 50%
Indicative measurements(1) 14% 14% 14% 33%

12.  The uncertainty (expressed at a 95 % confidence level) of the methods used for the assessment of ambient air concentrations shall be evaluated in accordance with the CEN Guide to the Expression of Uncertainty in Measurement (ENV 13005-1999)(20), the methodology of ISO 5725:1994, and the guidance provided in the CEN Report, ‘Air quality — Approach to uncertainty estimation for ambient air reference measurement methods’ (CR 14377:2002E). The percentages for uncertainty in the table in paragraph 11 are given for individual measurements, which are averaged over typical sampling times, for a 95 % confidence interval. The uncertainty of the measurements shall be interpreted as being applicable in the region of the appropriate target value. Fixed and indicative measurements shall be evenly distributed over the year in order to avoid skewing of results.

13.  The requirements for minimum data capture and time coverage do not include losses of data due to regular calibration or normal maintenance of the instrumentation. Twenty-four-hour sampling is required for the measurement of benzo(a)pyrene and polycyclic aromatic hydrocarbons. With care, individual samples taken over a period of up to one month may be combined and analysed as a composite sample, provided the method ensures that the samples are stable for that period. The three congeners benzo(b)fluoranthene, benzo(j)fluoranthene, benzo(k)fluoranthene may be difficult to resolve analytically in which case they may be reported as sum. The Secretary of State shall endeavour, in so far as practicable, to undertake twenty-four hour sampling for the measurement of arsenic, cadmium and nickel concentrations. Sampling shall be spread evenly over the weekdays and the year. For the measurement of deposition rates, the Secretary of State shall endeavour, in so far as practicable, to obtain monthly or weekly samples throughout the year.

14.  The Secretary of State may allow for use of wet only instead of bulk sampling if it can be demonstrated that the difference between them is within 10 %. Deposition rates shall generally be given as µg/m² per day.

15.  The Secretary of State may apply a minimum time coverage lower than indicated in the table, but not lower than 14 % for fixed measurements and 6 % for indicative measurements provided that he is satisfied that it can be demonstrated that the 95 % expanded uncertainty for the annual mean, calculated from the data quality objectives in the table according to ISO 11222:2002 — ‘Determination of the uncertainty of the time average of air quality measurements’ will be met.

(20)

European Committee for Standardisation (CEN) publication (copies may be obtained from CEN at 36, Rue de Stassart, B-1050, Brussels, Belgium http://www.cenorm.be). Back [20]