xmlns:atom="http://www.w3.org/2005/Atom"
9.—(1) A storage permit shall include at least the following—
(a)the name and address of a single person who is a licence holder and who is designated as the operator of the storage site;
(b)the precise location and delimitation of the storage site and storage complex, and any relevant information concerning the hydraulic unit;
(c)the operational requirements for storage, including—
(i)the total quantity of CO2 authorised to be stored;
(ii)the reservoir pressure limits; and
(iii)the maximum injection rates and pressures;
(d)the provisions relating to acceptance and injection of CO2, including composition of the CO2 stream;
(e)any other requirements relating to injection and storage that the authority considers necessary, in particular to prevent significant irregularities;
(f)requirements designed to prevent any undue interference with other uses of the area surrounding the storage site;
(g)the provisions relating to monitoring, including the monitoring plan;
(h)the provision relating to reporting, and notification of leakages and significant irregularities;
(i)the provisions relating to notification and implementation of changes, and to review and modification or revocation of the permit;
(j)the provisions relating to corrective measures, including the corrective measures plan;
(k)the conditions for closure of the storage site;
(l)the provisional post-closure plan; and
(m)the provisions relating to financial security.
(2) In this regulation, “provisions” means the provisions contained in Schedule 2.