4.—(1) An application for a permit to operate an installation which contains a SED installation shall, in addition to the information specified in paragraphs 1 and where applicable 2, include a description of the measures which are envisaged to guarantee in respect of that installation that the installation is designed, equipped and will be operated in such a manner that the requirements of Chapter V of the IED are met.
(2) That description shall include—
(a)where the operator wishes to use a reduction scheme, details of the proposed reduction scheme; and
(b)where there is used in the SED installation substances or mixtures which, because of their content of volatile organic compounds are classified as carcinogens, mutagens or toxic to reproduction under Regulation No 1272/2008(1) of the European Parliament and of the Council of 16 December 2008 on classification, labelling and packaging of substances and mixtures are assigned or need to carry the hazard statements H340, H350, H350i, H360D or H360F or the risk phrases R45, R46, R49, R60 or R61, a timetable for replacing such substances or mixtures, as far as possible, by less harmful substances or mixtures within the shortest possible time, taking into account the guidance referred to in Article 64 of the IED.
O.J. No. L 353, 31.12.2008, p1