1. Subject to paragraphs 2 and 3, the prescribed limits of error expressed in terms of “e”, the relevant verification scale interval of the device under test, shall be those set out in the Table.
Limits of error in excess or deficiency | |||
---|---|---|---|
Classification of Machine | upon passing as fit for use for trade | in relation to the obliteration of stamps | Number of verification scale intervals for loads – see Note |
Column 1 | Column 2 | Column 3 | Column 4 |
Class I | |||
(first part) | 0.5 e | 1 e | Not more than 50 000 e |
(second part) | 1 e | 2 e | more than 50 000 e and not more than 200 000 e |
(third part) | 1.5 e | 3 e | more than 200 000 e |
Class II | |||
(first part) | 0.5 e | 1 e | Not more than 5 000 e |
(second part) | 1 e | 2 e | more than 5 000 e and not more than 20 000 e |
(third part) | 1.5 e | 3 e | more than 20 000 e |
Class III | |||
(first part) | 0.5 e | 1 e | Not more than 500 e |
(second part) | 1 e | 2 e | more than 500 e and not more than 2 000 e |
(third part) | 1.5 e | 3 e | more than 2 000 e |
Class IIII | |||
(first part) | 0.5 e | 1 e | Not more than 50 e |
(second part) | 1 e | 2 e | more than 50 e and not more than 200 e |
(third part) | 1.5 e | 3 e | more than 200 e |