- Latest available (Revised)
- Original (As made)
This is the original version (as it was originally made). This item of legislation is currently only available in its original format.
6. The distance between a store and—
(a)any minor road or railway line shall be half; and
(b)any footpath, footway, lightly-used road or waterway shall be one-third,
the distance shown in column 2 of the Table corresponding to the quantity of explosives shown in column 1 of the Table.
1 | 2 | 3 | 4 | 5 | 6 |
---|---|---|---|---|---|
Quantity of explosives (kilograms) | Low density distance (metres) | High density distance (metres) | Vulnerable building distance (metres) | Reference zone radius (metres) | Maximum number of dwellings in reference zone |
0.1–25 | 101 | — | 101 | — | — |
25–50 | 107 | — | 107 | — | — |
50–75 | 112 | — | 112 | — | — |
75–100 | 118 | — | 118 | — | — |
100–150 | 128 | 142 | 128 | 257 | 81 |
150–200 | 139 | 156 | 139 | 278 | 96 |
200–300 | 161 | 180 | 161 | 322 | 128 |
300–400 | 183 | — | 183 | — | — |
400–450 | 193 | — | 193 | — | — |
450–500 | 204 | — | 204 | — | — |
500–600 | 204 | — | 216 | — | — |
600–700 | 204 | 231 | 238 | 408 | 206 |
700–800 | 204 | 238 | 260 | 408 | 206 |
800–900 | 204 | 245 | 280 | 408 | 206 |
900–1000 | 204 | 250 | 300 | 408 | 206 |
1000–1100 | 204 | 255 | 319 | 408 | 206 |
1100–1200 | 204 | 259 | 337 | 408 | 206 |
1200–1300 | 204 | 263 | 354 | 408 | 206 |
1300–1400 | 204 | 266 | 370 | 408 | 206 |
1400–1500 | 204 | 269 | 386 | 408 | 206 |
1500–1600 | 204 | 272 | 402 | 408 | 206 |
1600–1700 | 208 | 274 | 416 | 416 | 214 |
1700–1800 | 215 | 277 | 431 | 431 | 229 |
1800–1900 | 222 | 279 | 444 | 444 | 244 |
1900–2000 | 229 | 281 | 458 | 458 | 259 |
1 | 2 | 3 |
---|---|---|
Quantity of explosives (kilograms) | Low density distance (metres) | Vulnerable building distance (metres) |
0.1–25 | 141 | 141 |
25–50 | 160 | 160 |
50–75 | 180 | 180 |
75–100 | 199 | 199 |
100–150 | 230 | 230 |
150–200 | 256 | 256 |
200–300 | 293 | 293 |
300–400 | 320 | 320 |
400–450 | 331 | 331 |
450–500 | 340 | 340 |
500–600 | 355 | 355 |
600–700 | 367 | 367 |
700–800 | 377 | 377 |
800–900 | 385 | 385 |
900–1000 | 392 | 392 |
1000–1100 | 398 | 398 |
1100–1200 | 403 | 403 |
1200–1300 | 408 | 408 |
1300–1400 | 412 | 412 |
1400–1500 | 415 | 415 |
1500–1600 | 418 | 418 |
1600–1700 | 421 | 421 |
1700–1800 | 424 | 431 |
1800–1900 | 426 | 444 |
1900–2000 | 428 | 458 |
1 | 2 | 3 | 4 | 5 | 6 |
---|---|---|---|---|---|
Quantity of explosives (kilograms) | Low density distance (metres) | High density distance (metres) | Vulnerable building distance (metres) | Reference zone radius (metres) | Maximum number of dwellings in reference zone |
0.1–25 | 34 | 45 | 40 | 68 | 6 |
25–50 | 37 | 45 | 48 | 74 | 7 |
50–75 | 40 | 45 | 54 | 80 | 8 |
75–100 | 43 | 48 | 66 | 86 | 9 |
100–150 | 49 | 55 | 86 | 97 | 12 |
150–200 | 54 | 62 | 104 | 109 | 15 |
200–300 | 68 | 76 | 136 | 136 | 23 |
300–400 | 83 | — | 165 | — | — |
400–450 | 89 | — | 178 | — | — |
450–500 | 96 | — | 191 | — | — |
500–600 | 108 | — | 216 | — | — |
600–700 | 119 | — | 238 | — | — |
700–800 | 130 | — | 260 | — | — |
800–900 | 140 | — | 280 | — | — |
900–1000 | 150 | — | 300 | — | — |
1000–1100 | 159 | — | 319 | — | — |
1100–1200 | 168 | — | 337 | — | — |
1200–1300 | 177 | — | 354 | — | — |
1300–1400 | 185 | — | 370 | — | — |
1400–1500 | 193 | — | 386 | — | — |
1500–1600 | 201 | — | 402 | — | — |
1600–1700 | 208 | — | 416 | — | — |
1700–1800 | 215 | — | 431 | — | — |
1800–1900 | 222 | — | 444 | — | — |
1900–2000 | 229 | — | 458 | — | — |
1 | 2 | 3 | 4 | 5 | 6 |
---|---|---|---|---|---|
Quantity of explosives (kilograms) | Low density distance (metres) | High density distance (metres) | Vulnerable building distance (metres) | Reference zone radius (metres) | Maximum number of dwellings in reference zone |
0.1–10 | 23 | 30 | 40 | 46 | 3 |
10–20 | 29 | 35 | 42 | 57 | 4 |
20–30 | 33 | 39 | 44 | 65 | 5 |
30–40 | 36 | 42 | 46 | 71 | 6 |
40–50 | 38 | 44 | 48 | 76 | 7 |
50–60 | 40 | 46 | 48 | 80 | 8 |
60–70 | 42 | 48 | 52 | 84 | 9 |
70–80 | 43 | 50 | 57 | 87 | 9 |
80–90 | 44 | 52 | 61 | 89 | 10 |
90–100 | 45 | 55 | 66 | 91 | 10 |
100–110 | 46 | 57 | 70 | 93 | 11 |
110–120 | 47 | 59 | 74 | 95 | 11 |
120–130 | 48 | 62 | 78 | 97 | 12 |
130–140 | 49 | 64 | 82 | 98 | 12 |
140–150 | 50 | 66 | 86 | 100 | 12 |
150–160 | 51 | 68 | 90 | 102 | 13 |
160–170 | 52 | 71 | 93 | 104 | 13 |
170–180 | 53 | 73 | 97 | 106 | 14 |
180–190 | 54 | 75 | 101 | 108 | 14 |
190–200 | 55 | 78 | 104 | 110 | 15 |
200–300 | 68 | 101 | 136 | 136 | 23 |
300–400 | 83 | 124 | 165 | 165 | 34 |
400–450 | 89 | 135 | 178 | 178 | 39 |
450–500 | 96 | 138 | 191 | 191 | 45 |
500–600 | 108 | 144 | 216 | 216 | 57 |
600–700 | 119 | 150 | 238 | 238 | 70 |
700–800 | 130 | 156 | 260 | 260 | 83 |
800–900 | 140 | 162 | 280 | 280 | 97 |
900–1000 | 150 | 168 | 300 | 300 | 111 |
1000–1100 | 159 | 168 | 319 | 319 | 111 |
1100–1200 | 168 | — | 337 | — | — |
1200–1300 | 177 | — | 354 | — | — |
1300–1400 | 185 | — | 370 | — | — |
1400–1500 | 193 | — | 386 | — | — |
1500–1600 | 201 | — | 402 | — | — |
1600–1700 | 208 | — | 416 | — | — |
1700–1800 | 215 | — | 431 | — | — |
1800–1900 | 222 | — | 444 | — | — |
1900–2000 | 229 | — | 458 | — | — |
1 | 2 | 3 | 4 | 5 | 6 |
---|---|---|---|---|---|
Quantity of explosives (kilograms) | Low density distance (metres) | High density distance (metres) | Vulnerable building distance (metres) | Reference zone radius (metres) | Maximum number of dwellings in reference zone |
0.1–25 | 38 | 53 | 54 | 74 | 11 |
25–50 | 43 | 53 | 54 | 86 | 11 |
50–75 | 48 | 60 | 54 | 96 | 11 |
75–100 | 53 | 77 | 66 | 106 | 14 |
100–150 | 63 | 110 | 86 | 127 | 20 |
150–200 | 74 | 143 | 104 | 147 | 27 |
200–300 | 94 | 209 | 136 | 188 | 44 |
300–400 | 115 | 275 | 165 | 229 | 65 |
400–450 | 125 | 308 | 178 | 250 | 77 |
450–500 | 128 | 309 | 191 | 257 | 81 |
500–600 | 135 | 311 | 216 | 270 | 90 |
600–700 | 142 | 312 | 238 | 283 | 99 |
700–800 | 148 | 314 | 260 | 297 | 109 |
800–900 | 155 | 316 | 280 | 310 | 119 |
900–1000 | 162 | 318 | 300 | 324 | 129 |
1000–1100 | 169 | 319 | 319 | 337 | 140 |
1100–1200 | 175 | 321 | 337 | 350 | 152 |
1200–1300 | 182 | 323 | 354 | 364 | 163 |
1300–1400 | 189 | 325 | 370 | 377 | 176 |
1400–1500 | 195 | 326 | 386 | 391 | 188 |
1500–1600 | 202 | 328 | 402 | 404 | 202 |
1600–1700 | 209 | 330 | 416 | 417 | 215 |
1700–1800 | 215 | 332 | 431 | 431 | 229 |
1800–1900 | 222 | 333 | 444 | 444 | 244 |
1900–2000 | 229 | 335 | 458 | 458 | 259 |
1 | 2 | 3 |
---|---|---|
Quantity of explosives (kilograms) | Low density distance (metres) | Vulnerable building distance (metres) |
0.1–25 | 45 | 90 |
25–50 | 88 | 176 |
50–75 | 108 | 216 |
75–100 | 129 | 238 |
100–150 | 148 | 296 |
150–200 | 168 | 336 |
200–300 | 191 | 382 |
300–400 | 207 | 414 |
400–450 | 213 | 426 |
450–500 | 219 | 438 |
500–600 | 226 | 452 |
600–700 | 233 | 466 |
700–800 | 240 | 480 |
800–900 | 248 | 496 |
900–1000 | 256 | 512 |
1000–1100 | 259 | 518 |
1100–1200 | 262 | 524 |
1200–1300 | 266 | 532 |
1300–1400 | 270 | 540 |
1400–1500 | 274 | 548 |
1500–1600 | 278 | 556 |
1600–1700 | 282 | 564 |
1700–1800 | 286 | 572 |
1800–1900 | 288 | 576 |
1900–2000 | 292 | 592 |
1 | 2 | 3 |
---|---|---|
Quantity of explosives (kilograms) | Low density distance (metres) | Vulnerable building distance (metres) |
0.1–25 | 37 | 76 |
25–50 | 43 | 86 |
50–75 | 47 | 94 |
75–100 | 51 | 102 |
100–150 | 56 | 112 |
150–200 | 60 | 120 |
200–300 | 66 | 132 |
300–400 | 71 | 142 |
400–450 | 73 | 146 |
450–500 | 74 | 148 |
500–600 | 76 | 152 |
600–700 | 78 | 158 |
700–800 | 81 | 162 |
800–900 | 84 | 164 |
900–1000 | 87 | 174 |
1000–1100 | 88 | 176 |
1100–1200 | 89 | 178 |
1200–1300 | 90 | 180 |
1300–1400 | 91 | 182 |
1400–1500 | 92 | 184 |
1500–1600 | 94 | 188 |
1600–1700 | 95 | 190 |
1700–1800 | 97 | 194 |
1800–1900 | 99 | 198 |
1900–2000 | 101 | 202 |
1 | 2 |
---|---|
Quantity of explosives (kilograms) | Low density distance (metres) |
0.1–25 | — |
25–50 | 23 |
50–75 | 25 |
75–100 | 29 |
100–150 | 33 |
150–200 | 37 |
200–300 | 42 |
300–400 | 47 |
400–450 | 47 |
450–500 | 50 |
500–600 | 51 |
600–700 | 53 |
700–800 | 54 |
800–900 | 55 |
900–1000 | 63 |
1000–1100 | 70 |
1100–1200 | 71 |
1200–1300 | 72 |
1300–1400 | 73 |
1400–1500 | 74 |
1500–1600 | 75 |
1600–1700 | 76 |
1700–1800 | 78 |
1800–1900 | 79 |
1900–2000 | 80 |
1 | 2 |
---|---|
Quantity of explosives (kilograms) | Low density distance (metres) |
0.1–250 | — |
250–300 | 1 |
300–340 | 2 |
340–370 | 3 |
370–400 | 4 |
400–450 | 5 |
450–500 | 6 |
500–550 | 7 |
550–600 | 8 |
600–650 | 9 |
650–700 | 10 |
700–750 | 11 |
750–800 | 12 |
800–900 | 13 |
900–950 | 14 |
950–1000 | 15 |
1000–1100 | 16 |
1100–1150 | 17 |
1150–1200 | 18 |
1200–1300 | 19 |
1300–1350 | 20 |
1350–1400 | 21 |
1400–1450 | 22 |
1450–1550 | 23 |
1550–1600 | 24 |
1600–1650 | 25 |
1650–1700 | 26 |
1700–1800 | 27 |
1800–1850 | 28 |
1850–1900 | 29 |
1900–2000 | 30 |
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.
Explanatory Memorandum sets out a brief statement of the purpose of a Statutory Rule and provides information about its policy objective and policy implications. They aim to make the Statutory Rule accessible to readers who are not legally qualified and accompany any Northern Ireland Statutory Rule or Draft Northern Ireland Statutory Rule laid before the UK Parliament during the suspension of the Northern Ireland Assembly.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: