- Latest available (Revised)
- Original (As adopted by EU)
Commission Implementing Regulation (EU) 2016/799 of 18 March 2016 implementing Regulation (EU) No 165/2014 of the European Parliament and of the Council laying down the requirements for the construction, testing, installation, operation and repair of tachographs and their components (Text with EEA relevance)
When the UK left the EU, legislation.gov.uk published EU legislation that had been published by the EU up to IP completion day (31 December 2020 11.00 p.m.). On legislation.gov.uk, these items of legislation are kept up-to-date with any amendments made by the UK since then.
Legislation.gov.uk publishes the UK version. EUR-Lex publishes the EU version. The EU Exit Web Archive holds a snapshot of EUR-Lex’s version from IP completion day (31 December 2020 11.00 p.m.).
This is the original version as it was originally adopted in the EU.
This legislation may since have been updated - see the latest available (revised) version
This paragraph specifies the file structures of the Tachograph cards for storage of accessible data.
It does not specify card manufacturer dependent internal structures, such as e.g. file headers, nor storage and handling of data elements needed for internal use only such as,, or.
The maximum and minimum numbers of records are specified in this chapter for the different applications.
For the security conditions used in the access rules throughout this chapter please refer to chapter 3.3. In general the access mode ‘read’ denotes the READ BINARY command with even and if supported odd INS byte with the exception of the EF Sensor_Installation_Data on the workshop card, see TCS_156 and TCS_160. The access mode ‘update’ denotes the Update Binary command with even and if supported odd INS byte and the access mode ‘select’ the SELECT command.
Note: The short EF identifier SFID is given as decimal number, e.g. the value 30 corresponds to 11110 in binary.
The following abbreviation for the security condition is used in this table:
ALW OR SM-MAC-G2
The value ‘01’ indicates extended length field support for the T = 1 protocol.
The value ‘10’ indicates extended length field support for the T = 0 protocol.
The value ‘11’ indicates extended length field support for the T = 1 and the T = 0 protocol.
The following abbreviations for the security conditions are used in this table:
ALW OR SM-MAC-G2
ALW OR SM-MAC-G1 OR SM-MAC-G2
SM-MAC-G1 OR SM-MAC-G2
Note: The short EF identifier SFID is given as decimal number, e.g. the value 30 corresponds to 11110 in binary.
The following abbreviation for the security condition is used in this table:
ALW OR SM-MAC-G2
The following abbreviations for the security conditions are used in this table:
ALW OR SM-MAC-G2
ALW OR SM-MAC-G1 OR SM-MAC-G2
SM-MAC-G1 OR SM-MAC-G2
For the READ BINARYcommand with even INS byte:
(PLAIN-C AND SM-R-ENC-G1) OR (SM-C-MAC-G1 AND SM-R-ENC-MAC-G1) OR
(SM-C-MAC-G2 AND SM-R-ENC-MAC-G2)
For the READ BINARY command with odd INS byte (if supported): NEV
Note: The short EF identifier SFID is given as decimal number, e.g. the value 30 corresponds to 11110 in binary.
The following abbreviations for the security conditions are used in this table:
ALW OR SM-MAC-G2
For the Read Binary command with even INS byte: SM-C-MAC-G2 AND SM-R-ENC-MAC-G2
For the Read Binary command with odd INS byte (if supported): NEV
The following abbreviations for the security conditions are used in this table:
ALW OR SM-MAC-G2
ALW OR SM-MAC-G1 OR SM-MAC-G2
SM-MAC-G1 OR SM-MAC-G2
EXT-AUT-G1 OR SM-MAC-G1 OR SM-MAC-G2
Note: The short EF identifier SFID is given as decimal number, e.g. the value 30 corresponds to 11110 in binary.
The following abbreviation for the security condition is used in this table:
ALW OR SM-MAC-G2
The following abbreviations for the security conditions are used in this table:
ALW OR SM-MAC-G2
ALW OR SM-MAC-G1 OR SM-MAC-G2
SM-MAC-G1 OR SM-MAC-G2
EXT-AUT-G1 OR SM-MAC-G1 OR SM-MAC-G2
Note: The short EF identifier SFID is given as decimal number, e.g. the value 30 corresponds to 11110 in binary.
The following abbreviation for the security condition is used in this table:
ALW OR SM-MAC-G2
The Whole Regulation you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.
Would you like to continue?
The Schedules you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.
Would you like to continue?
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As adopted by EU): The original version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: