6. Determination of the ambient correction term Qcor
The ambient correction term is calculated as follows:
(a)
for conventional water heaters using electricity:
(b)
for conventional water heaters using fuels:
(c)
for heat pump water heaters:
Where:
the k-values are given in Table 8 for each load profile.
Table 8
k-values
| 3XS | XXS | XS | S | M | L | XL | XXL |
---|
k | 0,23 | 0,23 | 0,23 | 0,23 | 0,23 | 0,23 | 0,23 | 0,0 |
---|