- Latest available (Revised)
- Original (As adopted by EU)
Commission Delegated Regulation (EU) No 812/2013 of 18 February 2013 supplementing Directive 2010/30/EU of the European Parliament and of the Council with regard to the energy labelling of water heaters, hot water storage tanks and packages of water heater and solar device (Text with EEA relevance)
When the UK left the EU, legislation.gov.uk published EU legislation that had been published by the EU up to IP completion day (31 December 2020 11.00 p.m.). On legislation.gov.uk, these items of legislation are kept up-to-date with any amendments made by the UK since then.
Legislation.gov.uk publishes the UK version. EUR-Lex publishes the EU version. The EU Exit Web Archive holds a snapshot of EUR-Lex’s version from IP completion day (31 December 2020 11.00 p.m.).
This is the original version as it was originally adopted in the EU.
This legislation may since have been updated - see the latest available (revised) version
Technical parameters used for the calculations shall be measured in accordance with Annex VII.
The following parameters shall be calculated for water heaters under average climate conditions:
the water heating energy efficiency ηwh in %, rounded to one decimal place;
the annual electricity consumption AEC in kWh in terms of final energy, rounded to the nearest integer;
in addition, for water heaters using fuels under average climate conditions:
the annual fuel consumption AFC in kWh in terms of GCV, rounded to the nearest integer;
in addition, for solar water heaters under average climate conditions:
the heat generator water heating energy efficiency ηwh,nonsol in %, rounded to one decimal place;
the annual auxiliary electricity consumption Qaux in kWh in terms of final energy, rounded to one decimal place;
in addition, for solar water heaters and heat pump water heaters under colder and warmer climate conditions:
the parameters set out in points (a) to (c);
in addition for solar water heaters under average, colder and warmer climate conditions:
the annual non-solar heat contribution Qnonsol in kWh in terms of primary energy for electricity and/or in kWh in terms of GCV for fuels, rounded to one decimal place.
The water heating energy efficiency is calculated as follows:
For water-/brine-to-water heat pump water heaters, the electricity consumption of one or more ground water pumps shall be taken into account.
The water heating energy efficiency is calculated as follows:
Where:
The annual electricity consumption AEC in kWh in terms of final energy is calculated as follows:
The annual fuel consumption AFC in GJ in terms of GCV is calculated as follows:
The annual electricity consumption AEC in kWh in terms of final energy is calculated as follows:
The annual fuel consumption AFC in GJ in terms of GCV is calculated as follows:
The ambient correction term is calculated as follows:
Where:
the k-values are given in Table 8 for each load profile.
k-values
3XS | XXS | XS | S | M | L | XL | XXL | |
---|---|---|---|---|---|---|---|---|
k | 0,23 | 0,23 | 0,23 | 0,23 | 0,23 | 0,23 | 0,23 | 0,0 |
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As adopted by EU): The original version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: