ANNEX ILIST OF STUNNING METHODS AND RELATED SPECIFICATIONS

(as referred to in Article 4)

CHAPTER IISpecific requirements for certain methods

6.Electrical waterbath stunning of poultry

6.3.For animals referred to in Table 2, waterbath stunning shall be carried out in accordance with the minimum currents laid down therein, and animals shall be exposed to that current for a minimum duration of at least four seconds.

Table 2 —Electrical requirements for waterbath stunning equipment(average values per animal)

Frequency (Hz)

Chickens

Turkeys

Ducks and geese

Quails

< 200 Hz

100 mA

250 mA

130 mA

45 mA

From 200 to 400 Hz

150 mA

400 mA

Not permitted

Not permitted

From 400 to 1 500 Hz

200 mA

400 mA

Not permitted

Not permitted