xmlns:atom="http://www.w3.org/2005/Atom" xmlns:atom="http://www.w3.org/2005/Atom"

[F1ANNEX IIIA U.K. VERIFYING REAL DRIVING EMISSIONS

Appendix 3

Validation of PEMS and non-traceable exhaust mass flow rate U.K.

3. VALIDATION PROCEDURE FOR PEMS U.K.
3.2. PEMS validation procedure U.K.
3.2.1. PEMS installation U.K.

The PEMS shall be installed and prepared according to the requirements of Appendix 1. After the completion of the validation test until the start of the on-road test, the PEMS installation shall not be changed.

3.2.2. Test conditions U.K.

The validation test shall be conducted on a chassis dynamometer, as far as applicable, under type-approval conditions by following the requirements of Annex 4a to UN/ECE Regulation No 83, 07 series of amendments or any other adequate measurement method. It is recommended to conduct the validation test with the worldwide harmonised light vehicles test cycle (WLTC) as specified in Annex 1 to UNECE Global Technical Regulation No 15. The ambient temperature shall be within the range specified in point 5.2 of this Annex.

It is recommended to feed the exhaust flow extracted by the PEMS during the validation test back to the CVS. If this is not feasible, the CVS results shall be corrected for the extracted exhaust mass. If the exhaust mass flow rate is validated with an exhaust mass flow meter, it is recommended to cross-check the mass flow rate measurements with data obtained from a sensor or the ECU.

3.2.3. Data analysis U.K.

The total distance-specific emissions [g/km] measured with laboratory equipment shall be calculated following Annex 4a to UN/ECE Regulation No 83, 07 series of amendments. The emissions as measured with the PEMS shall be calculated according to point 9 of Appendix 4, summed to give the total mass of pollutant emissions [g] and then divided by the test distance [km] as obtained from the chassis dynamometer. The total distance-specific mass of pollutants [g/km], as determined by the PEMS and the reference laboratory system, shall be compared and evaluated against the requirements specified in point 3.3. For the validation of NO X emission measurements, humidity correction shall be applied following point 6.6.5 of Annex 4a to UN/ECE Regulation No 83, 07 series of amendments.]