This Annex specifies a method for the determination of the moisture content of dried cream.
For the purpose of this Annex, the following definition applies.
Moisture content: the loss of mass determined by the procedure specified in this International Standard.
It is expressed as a percentage by mass.
Drying of a test portion at 102 ± 2 °C to constant mass and weighing to determine the loss of mass.
Usual laboratory equipment and, in particular, the following:
It is important that the laboratory receive a test sample which is truly representative and has not been damaged or changed during transport or storage.
Sampling is not part of the method specified in this International Standard. A recommended sampling method is given in ISO 707|IDF 50.
Store the sample in such a way that deterioration and change in composition are prevented.
Thoroughly mix the test sample by repeatedly shaking and inverting the container (if necessary, after having transferred all test samples to an air-tight container of sufficient capacity to allow this operation to be carried out).
In case complete homogeneity is not attained by this procedure, take the test portions (for two single determinations) from the prepared test sample at two points as far apart as possible.
Transfer approximately 1 to 3 g of the prepared test sample (6) into the dish, cover with the lid and weigh to the nearest 1 mg recording the weight to 0,1 mg.
Take for the calculation the lowest mass recorded.
The moisture content, expressed in g/100g, is equal to:
where:
m0 is the mass, in grams, of the dish and the lid (7.1.2);
m1 is the mass, in grams, of the dish, the lid and the test portion before drying (7.2);
m2 is the mass, in grams, of the dish, the lid and the test portion after drying (7.3.4).
Report the result to two decimal places.
Note: The values for repeatability and reproducibility were derived from the results of an interlaboratory test (see Steiger, G. Bulletin of IDF No 285/1993, p. 21-28) carried out in accordance with IDF Standard 135B:1991. Milk and milk products — Precision characteristics of analytical methods — Outline of collaborative study procedure.
The absolute difference between two independent single test results, obtained using the same method on identical test material in the same laboratory by the same operator using the same equipment within a short interval of time, will in not more than 5 % of cases be greater than 0,20 g of moisture per 100 g of product.
The absolute difference between two independent single test results, obtained using the same method on identical test material in different laboratories by different operators using different equipment will in not more than 5 % of cases be greater than 0,40 g of moisture per 100 g of product.
The test report shall specify
all information necessary for the complete identification of the sample,
the sampling method used, if known,
the test method used with reference to this International Standard,
all operating details not specified in this International Standard, or regarded as optional, together with details of any incidents which may have influenced the test result(s).
The test result(s) obtained, and if the repeatability has been checked, the final quoted result obtained.
The Whole Regulation you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.
Would you like to continue?
The Schedules you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.
Would you like to continue?
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As adopted by EU): The original version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: