Search Legislation

Commission Regulation (EC) No 273/2008 (repealed)Show full title

Commission Regulation (EC) No 273/2008 of 5 March 2008 laying down detailed rules for the application of Council Regulation (EC) No 1255/1999 as regards methods for the analysis and quality evaluation of milk and milk products (repealed)

 Help about what version

What Version

More Resources

 Help about UK-EU Regulation

Legislation originating from the EU

When the UK left the EU, legislation.gov.uk published EU legislation that had been published by the EU up to IP completion day (31 December 2020 11.00 p.m.). On legislation.gov.uk, these items of legislation are kept up-to-date with any amendments made by the UK since then.

Close

This item of legislation originated from the EU

Legislation.gov.uk publishes the UK version. EUR-Lex publishes the EU version. The EU Exit Web Archive holds a snapshot of EUR-Lex’s version from IP completion day (31 December 2020 11.00 p.m.).

Status:

This is the original version as it was originally adopted in the EU.
This legislation may since have been updated - see the latest available (revised) version

DETERMINATION OF MOISTURE CONTENT IN DRIED CREAM

1.SCOPE

This Annex specifies a method for the determination of the moisture content of dried cream.

2.TERMS AND DEFINITIONS

For the purpose of this Annex, the following definition applies.

Moisture content: the loss of mass determined by the procedure specified in this International Standard.

It is expressed as a percentage by mass.

3.PRINCIPLE

Drying of a test portion at 102 ± 2 °C to constant mass and weighing to determine the loss of mass.

4.APPARATUS

Usual laboratory equipment and, in particular, the following:

4.1.Analytical balance, capable of weighing to the nearest 1 mg, with a readability of 0,1 mg.
4.2.Drying oven, well ventilated, capable of being maintained thermostatically at 102 ± 2 °C throughout the working space.
4.3.Desiccator, provided with freshly dried silica gel with hygrometric indicator or another effective desiccant.
4.4.Flat-bottomed dishes, depth of approximately 25 mm, diameter of approximately 50 mm, and made of appropriate material (for example glass, stainless steel, nickel or aluminium), provided with well-fitting, readily removable lids.
4.5.Bottles, with tight-fitting stoppers, for mixing the laboratory samples.

5.SAMPLING

It is important that the laboratory receive a test sample which is truly representative and has not been damaged or changed during transport or storage.

Sampling is not part of the method specified in this International Standard. A recommended sampling method is given in ISO 707|IDF 50.

Store the sample in such a way that deterioration and change in composition are prevented.

6.PREPARATION OF TEST SAMPLE

Thoroughly mix the test sample by repeatedly shaking and inverting the container (if necessary, after having transferred all test samples to an air-tight container of sufficient capacity to allow this operation to be carried out).

In case complete homogeneity is not attained by this procedure, take the test portions (for two single determinations) from the prepared test sample at two points as far apart as possible.

7.PROCEDURE

7.1.Preparation of the dish
7.1.1.Heat an uncovered dish and its lid (4.4) in the oven (4.2), set at 102 ± 2 °C, for at least 1 h.
7.1.2.Place the lid on the dish, transfer the covered dish to the desiccator (4.3), allow to cool to the temperature of the balance room and weigh to the nearest 1 mg recording the weight to 0,1 mg.
7.2.Test portion

Transfer approximately 1 to 3 g of the prepared test sample (6) into the dish, cover with the lid and weigh to the nearest 1 mg recording the weight to 0,1 mg.

7.3.Determination
7.3.1.Uncover the dish and place it with its lid in the oven (4.2), set at 102 ± 2 °C, for 2 h.
7.3.2.Replace the lid, transfer the covered dish to the desiccator, allow to cool to the temperature of the balance room and weigh to the nearest 1 mg recording the weight to 0,1 mg.
7.3.3.Uncover the dish and heat it again, with its lid, in the oven for 1 h. Then repeat operation 7.3.2.
7.3.4.Repeat the heating and the weighing procedure until the mass decreases by 1 mg or less, or increases between two successive weightings.

Take for the calculation the lowest mass recorded.

8.CALCULATION AND EXPRESSION OF RESULTS

8.1.Calculation

The moisture content, expressed in g/100g, is equal to:

where:

m0 is the mass, in grams, of the dish and the lid (7.1.2);

m1 is the mass, in grams, of the dish, the lid and the test portion before drying (7.2);

m2 is the mass, in grams, of the dish, the lid and the test portion after drying (7.3.4).

Report the result to two decimal places.

9.PRECISION

Note: The values for repeatability and reproducibility were derived from the results of an interlaboratory test (see Steiger, G. Bulletin of IDF No 285/1993, p. 21-28) carried out in accordance with IDF Standard 135B:1991. Milk and milk products — Precision characteristics of analytical methods — Outline of collaborative study procedure.

9.1.Repeatability

The absolute difference between two independent single test results, obtained using the same method on identical test material in the same laboratory by the same operator using the same equipment within a short interval of time, will in not more than 5 % of cases be greater than 0,20 g of moisture per 100 g of product.

9.2.Reproducibility

The absolute difference between two independent single test results, obtained using the same method on identical test material in different laboratories by different operators using different equipment will in not more than 5 % of cases be greater than 0,40 g of moisture per 100 g of product.

10.TEST REPORT

The test report shall specify

  • all information necessary for the complete identification of the sample,

  • the sampling method used, if known,

  • the test method used with reference to this International Standard,

  • all operating details not specified in this International Standard, or regarded as optional, together with details of any incidents which may have influenced the test result(s).

The test result(s) obtained, and if the repeatability has been checked, the final quoted result obtained.

Back to top

Options/Help

Print Options

You have chosen to open the Whole Regulation

The Whole Regulation you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.

Would you like to continue?

You have chosen to open Schedules only

The Schedules you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.

Would you like to continue?

Close

Legislation is available in different versions:

Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.

Original (As adopted by EU): The original version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.

Close

Opening Options

Different options to open legislation in order to view more content on screen at once

Close

More Resources

Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as adopted version that was used for the EU Official Journal
  • lists of changes made by and/or affecting this legislation item
  • all formats of all associated documents
  • correction slips
  • links to related legislation and further information resources
Close

More Resources

Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as adopted version that was used for the print copy
  • correction slips

Click 'View More' or select 'More Resources' tab for additional information including:

  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • links to related legislation and further information resources