Search Legislation

Commission Regulation (EC) No 273/2008 (repealed)Show full title

Commission Regulation (EC) No 273/2008 of 5 March 2008 laying down detailed rules for the application of Council Regulation (EC) No 1255/1999 as regards methods for the analysis and quality evaluation of milk and milk products (repealed)

 Help about what version

What Version

More Resources

 Help about UK-EU Regulation

Legislation originating from the EU

When the UK left the EU, legislation.gov.uk published EU legislation that had been published by the EU up to IP completion day (31 December 2020 11.00 p.m.). On legislation.gov.uk, these items of legislation are kept up-to-date with any amendments made by the UK since then.

Close

This item of legislation originated from the EU

Legislation.gov.uk publishes the UK version. EUR-Lex publishes the EU version. The EU Exit Web Archive holds a snapshot of EUR-Lex’s version from IP completion day (31 December 2020 11.00 p.m.).

Status:

This is the original version as it was originally adopted in the EU.
This legislation may since have been updated - see the latest available (revised) version

ANNEX XIX(Article 15)

DETERMINATION OF MOISTURE IN ACID BUTTERMILK POWDER

1.SCOPE

To determine the moisture content of acid buttermilk powder originally intended for animal feedingstuffs.

2.PRINCIPLE

The sample is dried under vacuum. The loss of mass is determined by weighing.

3.APPARATUS

3.1.Analytical balance, capable of weighing to the nearest 1 mg, with a readability of 0,1 mg
3.2.Dishes of non-corrodible metal or of glass with lids ensuring airtight closure; working surface allowing the test sample to be spread at about 0,3 g/cm2
3.3.Adjustable electrically heated vacuum oven fitted with an oil pump and a mechanism for introducing hot air dried through a tower containing for example calcium oxide or calcium sulphate (containing moisture indicator)
3.4.Desiccator with an efficient drying agent
3.5.Drying oven ventilated, thermostatically controlled, at 102 ± 2 °C.

4.PROCEDURE

Heat a dish (3.2) with its lid in the oven (3.5) for at least one hour. Place the lid on the container, immediately transfer to a desiccator (3.4) allow to cool to room temperature and weigh to the nearest 1 mg, recording the mass to 0,1 mg.

Uncover the dish and transfer about 5g of sample into the dish and weigh to the nearest 1 mg, recording the mass to 0,1 mg. Place the dish with its lid in the vacuum oven (3.3) preheated to 83 °C. To prevent the oven temperature from falling unduly, introduce the dish as rapidly as possible.

Bring the pressure up to 100 Torr (13,3 kPa) and leave to dry to constant weight (approximately 4 hours) at this pressure in a current of hot dry air.

Reckon drying time from the moment when the oven returns to 83 °C. Carefully bring the oven back to atmospheric pressure. Open the oven, place the lid on the dish immediately, remove the dish from the oven, leave to cool for 30 to 45 minutes in a desiccator (3.4) and weigh to the nearest 1 mg recording the mass to 0,1 mg. Dry for an additional 30 minutes in the vacuum oven (3.3) at 83 °C and reweigh. Repeat the heating and weighing procedure until the mass of the dish with its lid decreases by 1 mg or less, or increases between two successive weighings. Take for the calculation the lowest mass recorded.

5.CALCULATION

% Moisture = (m1 – m2) / (m1 – m0) × 100 %

Where:

m0

is the mass of the dish and the lid;

m1

is the mass of the dish, the lid and the test portion before drying;

m2

is the mass of the dish, the lid and the test portion after drying.

Record the result to the nearest 0,1 g / 100 g.

6.PRECISION

6.1.Repeatability limit

The absolute difference between two independent single test results, obtained using the same method on identical test material in the same laboratory by the same operator using the same equipment within a short interval of time, will in not more than 5 % of the cases be greater that 0,4 g water/ 100 g buttermilk powder.

6.2.Reproducibility limit

The absolute difference between two independent single test results, obtained using the same method on identical test material in different laboratories by different operators using different equipment will in not more than 5 % of cases be greater than 0,6 g water/100 g acid buttermilk powder.

6.3.Source of precision data

The precision data were determined from an experiment conducted in 1995 involving eight laboratories and 12 samples (6 blind duplicates).

Back to top

Options/Help

Print Options

You have chosen to open the Whole Regulation

The Whole Regulation you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.

Would you like to continue?

You have chosen to open Schedules only

The Schedules you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.

Would you like to continue?

Close

Legislation is available in different versions:

Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.

Original (As adopted by EU): The original version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.

Close

Opening Options

Different options to open legislation in order to view more content on screen at once

Close

More Resources

Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as adopted version that was used for the EU Official Journal
  • lists of changes made by and/or affecting this legislation item
  • all formats of all associated documents
  • correction slips
  • links to related legislation and further information resources
Close

More Resources

Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as adopted version that was used for the print copy
  • correction slips

Click 'View More' or select 'More Resources' tab for additional information including:

  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • links to related legislation and further information resources