xmlns:atom="http://www.w3.org/2005/Atom" xmlns:atom="http://www.w3.org/2005/Atom"

ANNEX VIIIU.K.TEST METHODS AND ANALYTICAL METHODS

5.Preliminary notesU.K.

5.3.Deionised waterU.K.

5.3.1.Ethanol, C2H5OH 95 % (v/v) (permissible denaturant: methyl-ethyl ketone or methanol)U.K.
5.3.2.Isopropanol/water mixture (50/50 v/v):U.K.
5.3.3.50 parts by volume isopropanol, CH3CHOH.CH3, andU.K.
5.3.4.0,3 mol NH4HCO3 in 1 000 ml of an isopropanol/water mixture consisting of 60 parts by volume isopropanol and 40 parts by volume water (5.3.1)U.K.
5.3.5.Anion exchanger (AAT), macro-porous, Merck Lewatit MP 7080 (70-150 mesh) or equivalentU.K.
5.3.6.Hydrochloric acid, 10 % HCl w/wU.K.
5.3.7.2 000 ml round-bottomed flask with ground glass stopper and reflux condenserU.K.
5.3.8.90 mm diameter suction Filter (heatable) for filter papersU.K.
5.3.9.2 000 ml filter flaskU.K.
5.3.10.Exchange columns with heating jacket and tap: inner tube 60 mm in diameter and 450 mm in height (see Figure 4)U.K.
5.3.11.Water-bathU.K.
5.3.12.Vacuum drying ovenU.K.
5.3.13.ThermostatU.K.
5.3.14.Rotary evaporatorU.K.
5.3.15.Preparation of extract and separation of non-ionic active agentsU.K.