ANNEX IVU.K.

PART IU.K.SPECIFIC REQUIREMENTSGAS METERS

2. Maximum permissible error (MPEs) U.K.

2.1.Gas meter indicating the volume at metering conditions or massU.K.

Table 1
Class1,51,0
Qmin ≤ Q < Qt3 %2 %
Qt ≤ Q ≤ Qmax1,5 %1 %

The gas meter shall not exploit the MPEs or systematically favour any party.

2.2.For a gas meter with temperature conversion, which only indicates the converted volume, the MPE of the meter is increased by 0,5 % in a range of 30 °C extending symmetrically around the temperature specified by the manufacturer that lies between 15 °C and 25 °C. Outside this range, an additional increase of 0,5 % is permitted in each interval of 10 °C.U.K.