Article 13U.K.Conformity assessment procedures
1.The conformity of instruments to the essential requirements set out in Annex I may be established by either of the following conformity assessment procedures as selected by the manufacturer:
(a)Module B as set out in point 1 of Annex II, followed either by Module D as set out in point 2 of Annex II, or by Module F as set out in point 4 of Annex II.
However, Module B shall not be compulsory for instruments which do not use electronic devices and the load-measuring device of which does not use a spring to balance the load. For those instruments not submitted to Module B, Module D1 as set out in point 3 of Annex II or Module F1 as set out in point 5 of Annex II shall apply;
(b)Module G as set out in point 6 of Annex II.
2.The documents and correspondence relating to the conformity assessment procedures referred to in paragraph 1 shall be drawn up in one of the official languages of the Member State where those procedures are carried out, or in a language accepted by the body notified in accordance with Article 19.