Operating conditions during testU.K.
Test under loadU.K.
The engine of the machine shall operate at the nominal speed indicated by the manufacturer. All working units shall be activated and operate at the following speeds: | |
conveying system | at least 10 % of maximum value |
spreading system | at least 40 % of maximum value |
tamper (speed, stroke) | at least 50 % of maximum value |
vibrators (speed, unbalance moment) | at least 50 % of maximum value |
pressure bars (frequency, pressure) | at least 50 % of maximum value |
Period of observationU.K.
The period of observation shall at least be 15 seconds