First Commission Directive of 13 November 1979 laying down Community methods of analysis for testing certain partly or wholly dehydrated preserved milk for human consumption (79/1067/EEC)

4.APPARATUSU.K.

4.1.Analytical balance.U.K.
4.2.Dishes, preferably of nickel, aluminium, stainless steel or glass. The dishes must have lids which fit very well but which can readily be removed. Suitable dimensions are: diameter 60 to 80 mm and depth about 25 mm.U.K.
4.3.Atmospheric-pressure drying oven, well ventilated, thermostatically controlled with temperature regulation (at 102 oC ± 1 oC). The temperature should be uniform throughout the oven.U.K.
4.4.Desiccator, containing freshly activated silica gel with a water content indicator or an equivalent desiccant.U.K.