Commission Decision

of 15 May 2007

amending Decision 2003/43/EC establishing the classes of reaction-to-fire performance for certain construction products as regards wood-based panels

(notified under document number C(2007) 2045)

(Text with EEA relevance)

(2007/348/EC)

THE COMMISSION OF THE EUROPEAN COMMUNITIES,

Having regard to the Treaty establishing the European Community,

Having regard to Council Directive 89/106/EEC of 21 December 1988 on the approximation of laws, regulations and administrative provisions of the Member States relating to construction products(1), and in particular Article 20(2) a thereof,

Whereas:

(1) Commission Decision 2003/43/EC(2) establishes classes of reaction-to-fire performance for certain construction products.

(2) Decision 2003/43/EC needs to be further adapted to take account of technical progress regarding wood-based panels.

(3) Decision 2003/43/EC should therefore be amended accordingly.

(4) The measures provided for in this Decision are in accordance with the opinion of the Standing Committee on Construction,

HAS ADOPTED THIS DECISION:

Article 1U.K.

The Annex to Decision 2003/43/EC is amended as set out in the Annex to this Decision.

Article 2U.K.

This Decision is addressed to the Member States.

Done at Brussels, 15 May 2007.

For the Commission

Günter Verheugen

Vice-President

ANNEXU.K.

In the Annex to Decision 2003/43/EC, Table 1 is replaced by the following:

Table 1

Classes of reaction to fire performance for wood-based panels

a

Mounted without an air gap directly against class A1 or A2-s1, d0 products with minimum density 10 kg/m3 or at least class D-s2, d2 products with minimum density 400 kg/m3.

b

A substrate of cellulose insulation material of at least class E may be included if mounted directly against the wood-based panel, but not for floorings.

c

Mounted with an air gap behind. The reverse face of the cavity shall be at least class A2-s1, d0 products with minimum density 10 kg/m3.

d

Mounted with an air gap behind. The reverse face of the cavity shall be at least class D-s2, d2 products with minimum density 400 kg/m3.

e

Veneered, phenol- and melamine-faced panels are included for class excl. floorings.

f

A vapour barrier with a thickness up to 0,4 mm and a mass up to 200 g/m2 can be mounted in between the wood-based panel and a substrate if there are no air gaps in between.

g

Class as provided for in Table 1 of the Annex to Decision 2000/147/EC.

h

Class as provided for in Table 2 of the Annex to Decision 2000/147/EC.

ProductEN product standardEnd use conditionfMinimum density(kg/m3)Minimum thickness(mm)Classg(excluding floorings)Classh(floorings)
Cement-bonded particleboardaEN 634-2without an air gap behind the panel1 00010B-s1, d0Bfl-s1
Fibreboard, hardaEN 622-2without an air gap behind the wood-based panel9006D-s2, d0Dfl-s1
Fibreboard, hardcEN 622-2with a closed air gap not more than 22 mm behind the wood-based panel9006D-s2, d2
Particleboarda,b,eEN 312without an air gap behind the wood-based panel6009D-s2, d0Dfl-s1
Fibreboard, hard and mediuma,b,e

EN 622-2

EN 622-3

MDFa,b,eEN 622-5
MDFa,b,eEN 300
Plywooda,b,eEN 636-“-4009D-s2, d0Dfl-s1
Solid wood panela,b,eEN 1335312
Flaxboarda,b,eEN 15197-“-45015D-s2, d0Dfl-s1
Particleboardc,eEN 312with a closed or an open air gap not more than 22 mm behind the wood-based panel6009D-s2, d2
Fibreboard, hard and mediumc,e

EN 622-2

EN 622-3

MDFc,eEN 622-5
OSBc,eEN 300
Plywoodc,eEN 636-“-4009D-s2, d2
Solid wood panelc,eEN 1335312
Particleboardd,eEN 312with a closed air gap behind the wood-based panel60015D-s2, d0Dfl-s1
Fibreboard, mediumd,eEN 622-3
MDFd,eEN 622-5
OSBd,eEN 300
Plywoodd,eEN 636-“-40015D-s2, d1Dfl-s1
Solid wood paneld,eEN 13353D-s2, d0
Flaxboardd,eEN 15197-“-45015D-s2, d0Dfl-s1
Particleboardd,eEN 312with an open air gap behind the wood-based panel60018D-s2, d0Dfl-s1
Fibreboard, mediumd,eEN 622-3
MDFd,eEN 622-5
OSBd,eEN 300
Plywoodd,eEN 636-“-40018D-s2, d0Dfl-s1
Solid wood paneld,eEN 13353
Flaxboardd,eEN 15197-“-45018D-s2, d0Dfl-s1
ParticleboardeEN 312any6003EEfl
OSBeEN 300
MDFeEN 622-5-“-4003EEfl
2509EEfl
PlywoodeEN 636-“-4003EEfl
Fibreboard, hardeEN 622-2-“-9003EEfl
Fibreboard, mediumeEN 622-3-“-4009EEfl
Fibreboard, softEN 622-4-“-2509EEfl