ANEX IIU.K.

IV. DETERMINATION OF TOTAL NITROGEN CONTENT U.K.

9.MODIFIED PROCEDURESU.K.

9.1.Use a block digestion apparatus fitted with cylindrical flasks, instead of the digestion apparatus and the Kjeldahl flasks described in 5.5. and 5.1. In this case to identify potential trouble, each spot has to be checked individually (6.7.).U.K.
9.2.Use of steam distillation instead of direct heating of the flasks (6.4.). When the apparatus does not allow the use of distilled water, care should be taken that the water does not contain acid or alkaline volatiles.U.K.
9.3.A test portion of 1 g of milk (semi-macro Kjeldahl) can be used instead of 5 g (6.1.) provided:U.K.

Note: Using one or more of these options is acceptable only if the repeatability value (8.2.1.) and the two accuracy tests results (6.7.) are in accordance with the requirements given in this method.U.K.